Before calling for service, Step, Error code table – Sharp XE-A113 User Manual
Page 33
31
Part
1
QUICK START GUIDE
Part
2
Part
3
BEFORE CALLING FOR SERVICE
The malfunctions shown in the left-hand column below, labelled “Fault,” do not necessarily indicate functional
faults of the machine. It is therefore advisable to refer to “Checking” shown in the right-hand column before
calling for service.
Error code table
When the following error codes are displayed, press the
l
key and take a proper action according to the table
below.
Fault
Checking
The display won’t illuminate even when the mode switch
is turned to any other position than “ ”.
• Is power supplied to the electrical outlet?
• Is the power cord plug out or loosely connected to the
AC outlet?
(2)
The display shows symbols that do not make sense.
• Has the machine been initialized properly as shown in
“PREPARING THE CASH REGISTER” on page 8?
(Note that initialization clears all the data and programmed
settings stored in memory.)
(1)
The display is illuminated, but the whole machine
refuses registrations.
• Is a clerk code assigned to the register?
• Is the mode switch set properly at the “REG” position?
(3)
No receipt is issued.
• Is the paper roll properly installed?
• Is there a paper jam?
• Is the receipt function in the “OFF” status?
• Is the print roller arm securely locked?
(4)
No journal paper is taken up.
• Is the take-up spool installed on the bearing properly?
• Is there a paper jam?
(5)
Printing is unusual.
• Is the print roller arm securely locked?
Open the print roller arm, and lock the arm by following
the instruction of installation.
• Is the paper roll properly installed?
• Are the print head/sensor/roller clean?
(6)
Continuous printing stops.
• Display shows “– – – – –”.
Printing will automatically restart after several seconds.
(7)
STEP
8
Error
Error status
Action
code
E01
Registration error
Make a correct key entry.
E02
Misoperation error
Make a correct key entry.
E03
Undefined code is entered.
Enter a correct code
E07
Memory is full (in the
a
key programming).
Program the
a
key within 25 steps.
E11
Compulsory depression of the
s
key for
Press the
s
key and continue the operation.
direct finalization
E12
Compulsory tendering
Make a tendering operation.
E32
No entry of a clerk code
Make a clerk code entry.
E34
Overflow limitation error
Make a registration within a limit of entry.
E35
The open price entry is inhibited.
Make a preset price entry.
E36
The preset price entry is inhibited.
Make an open price entry.
E37
The direct finalization is inhibited.
Make a tendering operation.
E67
Subtotal void is not allowed.
Finalize the transaction, and correct the wrong entries in the
mode.
A113_1 Quick Start Guide 06.9.11 6:35 PM Page 31