Cleaning water inlet strainers – Bosch WFR 2450 User Manual
Page 32
32
q Carefully remove the pump cap.
q Remove any loose debris/lint from inside the
pump and clean the pump. The pump impeller
must be able to rotate.
Clean any remaining water or lint from the
threads of the pump cap and pump housing.
q Attach and tighten the pump cap.
q Attach and close the cover plate.
To prevent unused detergent from flowing into the
drain during the next wash cycle:
q Pour 1 litre/1 ¾ pt of water into chamber II.
q Select the Drain program.
Cleaning water inlet strainers
This is necessary if very little or no water flows into
the washing machine.
First release the water pressure in the supply
hoses:
q Turn off the water taps.
q Turn the program selector to any program
(except Spin or Drain).
q Press Start/Pause button and wait for Water
tap closed?" message.
q Turn the program selector to Off.