beautypg.com

Appendix 2 – Baracoda BaracodaPencil2 User Manual

Page 38

background image

BaracodaPencil2 – Programming Guide v1.7

- 38 -

Data Capture

for Workforce

in Motion

APPENDIX 2

The SI prefix is a two or three character string:

] c m where

] : SI indicator

c : Symbology Identification

m : Modifier characters (optional)

Symbology Character

A

Code 39

B

Telepen

C

Code 128

D

Code One

E

EAN/UPC

F

Codabar

G

Code 93

H

Code 11

I

ITF 25

K

Code 16K

L

PDF417

M

MSI code

N

Anker Code

O

Codablock

P

Plessey Code

R

Straight 2 of 5 (two bar start/stop codes)

S

Straight 2 of 5 (three bar start/stop codes)

T

Code 49

X

Other Bar code

Z

Non Barcode data

Modifier Characters

The modifier character is determined by summing the option values of each symbology. If the sum is greater