Blodgett KLT-G Series User Manual
Page 8

8
2.0 INSTALLATION (Continued) 
 
WATER CONNECTION  
 
On units equipped with an optional water fill valve connect a water line (minimum 1/4") to the 
valve with a 1/4" NPT female fitting. Units with dual (hot and cold) valves must have the hot 
water line connected to side with the hot water valve (red) and cold water line to the cold water 
valve (blue). Plastic or rubber hose is not recommended, as it may melt against the hot kettle 
side. 
 
ELECTRICAL CONNECTION 
 
WARNING: Do not connect the kettle to the electrical supply until after the gas 
connection has been made.
 
 
1. 120 VAC - 60 Hz - Single Phase 
 
WARNING: ELECTRICAL GROUNDING INSTRUCTIONS 
This appliance is equipped with a three-prong (grounding) plug for your protection 
against shock hazard and should be plugged directly into a properly grounded 
three-prong receptacle. Do not cut or remove the grounding prong from this plug. 
(120V units only).
 
 
Units with this electrical rating are factory supplied with a three-wired cord and three-prong plug 
which fits any standard 120V, three-prong grounded receptacle. A separate 15 amp supply is 
needed for each unit. 
 
1. 208/240 VAC - 60 Hz - Single and Three Phase 
 
Units with this electrical rating are factory equipped with a transformer. To connect supply 
wires, remove cover from right console. Route supply wires and ground wire through the 
hole in the console with a strain relief fitting. Connect wires to the terminal block in the rear 
of the right console. Connect ground wire to lug. Replace cover. Three-phase units are 
wired as above, using only two supply wires. The third supply wire is not connected and 
must be properly terminated. 
 
1. 220 VAC - 50 Hz - Single Phase 
 
 
Units equipped with this voltage ratings should be wired exactly as in (2.) above.