3.0 OPERATION (Continued)
THERMOSTAT
The thermostat selects the desired internal kettle operating temperature. The thermostat must
be set at a desired setting in order for the burner to ignite.
For Reference:
DIAL SETTING
C
F
1
15
60
2
27
81
3
40
104
4
53
127
5
67
153
6
81
178
7
95
203
8
108
226
9
122
252
10
135
275
PRESSURE GAUGE
The pressure gauge indicates the internal operating pressure of the kettle. When cold, the
gauge should point to the green vacuum zone. If it does not, refer to “Re-establishing Vacuum”
section. Under normal operation with the kettle empty (thermostat set at 10 or 275
F) the
pressure should reach 30 psi. When loaded the pressure may be considerably less.
SIGHT GLASS
The sight glass indicates the minimum and maximum water level within the kettle. If water level
falls below minimum level more distilled water should
be added. See “Adding Water” in Service
section.