Blodgett KLT-G Series User Manual
Page 12
12
3.0 OPERATION (Continued)
FRONT PANEL CONTROLS
POWER SWITCH
This switch turns the main power to the unit on and off. It must be turned on to heat the kettle.
It should be turned off when the kettle will not be in use for long periods.
(GREEN) IGNITION LIGHT
This light is on whenever the main burner gas is on.
(RED) COOKING LIGHT
This light is on when the thermostat is calling for heat.
(AMBER) LOW WATER LIGHT
All kettles are supplied with sufficient distilled water in pressurized jacket. If at any time the
water level falls below that required for proper operation, the kettle will not heat and this light will
come on. See “Adding Water” in Service section.