Blodgett KLT-G Series User Manual
Page 10

10
3.0 OPERATION 
 
CAUTION: If you smell gas during the lighting procedure, immediately shut off the 
gas supply until the leak has been corrected.
 
 
WARNING: In the event of main burner ignition failure, a 5 minute purge period 
must be observed prior to re-establishing ignition source.
 
 
WARNING: In the event you smell gas, shut down equipment at the main shut off 
valve and contact the local gas company or gas supplier for service.
 
GAS CONTROL INSTRUCTIONS 
 
The units do not require “lighting” the pilot with a match. 
 
A. Lighting 
 
 
1. Open manual gas shut off valve. 
 
2. Set thermostat to OFF, and kettle in fully upright position, turn power switch ON. 
 
3. Set thermostat to maximum, initiating a 30 second pre-
purge. Red “COOKING” pilot will
come on, and after 30 seconds, the green “IGNITION” pilot will come on, lighting the main 
burners. 
Contact the factory, the factory representative or a local service company to perform
maintenance and repairs should the appliance malfunction.
NOTE: Unit is shipped with gas combination valve turned “on”.