Olympus EVOLT E-500 User Manual
Page 197
197
Information
12
In
fo
rm
atio
n
Exposure mode
: (1) AUTO: Full auto
(2) P: Program AE (Program shift can be performed)
(3) A: Aperture priority AE
(4) S: Shutter priority AE
(5) M: Manual
ISO sensitivity
: 100 - 400 (High ISO values (400 - 1600) are available)
Exposure compensation : Exposure can be adjusted in 1/3, 1/2 or 1 EV step within a
range of ± 5 EV.
White balance
Product type
: CCD
Mode setting
: Auto, Preset WB (7 settings), Customized WB ,
One-touch WB
Recording
Memory
: CF card (Compatible with Type I and II)
Microdrive (Compatible with FAT 32)
xD-Picture Card
Recording system
: Digital recording, TIFF (non-compression), JPEG (in
accordance with Design rule for Camera File system (DCF)),
RAW Data
Applicable standards
: Exif 2.2, Digital Print Order Format (DPOF), PRINT Image
Matching III, PictBridge
Playback
Playback mode
: Single-frame playback, Close-up playback, Index display,
Image rotation, Slideshow, Light box display, Calendar display
Information display
: Information display, Histogram display
Drive
Drive mode
: Single-frame shooting, Sequential shooting, Self-timer,
Remote control
Sequential shooting
: 2.5 frames/sec. (Max. no. of storable sequential pictures:
4 frames in RAW/TIFF)
Self-timer
: Operation time: 12 sec., 2 sec.
Optical remote control
: Operation time: 2 sec., 0 sec. (instantaneous shooting) (RM-1
Remote Control (optional))
Flash
Synchronization
: Synchronized with the camera at 1/180 sec. or less
Flash control mode
: TTL-AUTO (TTL pre-flash mode), AUTO, MANUAL
External flash attachment: Hot shoe
External connector
USB connector/Multi-connector
Power supply
Battery
: BLM-1 Li-ion Battery x1/CR123A lithium battery x3 (for use
with LBH-1 Lithium Battery Holder)
Dimensions/weight
Dimensions
: 129.5 mm (W) x 94.5 mm (H) x 66 mm (D) (5.1" x 3.7" x 2.6")
(excluding protrusions)
Weight
: Approx.435 g (1.0 Ib.) (without battery)
Operating environment
Temperature
: 0 - 40°C (32°F - 104°F) (operation)/
-20 - 60°C (-4°F - 140°F) (storage)
Humidity
: 30 - 90 % (operation)/10 - 90 % (storage)
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT ANY NOTICE
OR OBLIGATION ON THE PART OF THE MANUFACTURER.