577d -- -- a – Bryant EVOLUTION 577D----A User Manual
Page 8
8
Table 1—Physical Data (Con’t) -- Unit 577D----A
UNIT SIZE
48090
48115
48130
60090
60115
60130
NOMINAL COOLING CAPACITY (ton)
4
4
4
5
5
5
NOMINAL HEATING CAPACITY (Btu)
90,000
115,000
130,000
90,000
115,000
130,000
SHIPPING WEIGHT (lb)
(kg)
558
253
558
253
558
253
609
276
609
276
609
276
COMPRESSORS
Quantity
2--- Stage Scroll
1
REFRIGERANT: PURON (R---410A)
Quantity (lb)
(kg)
15.3
6.9
15.3
6.9
15.3
6.9
15.8
7.2
15.8
7.2
15.8
7.2
REFRIGERANT METERING DEVICE
TXV
Size
4 Ton
4 Ton
4 Ton
5 Ton
5 Ton
5 Ton
OUTDOOR FAN
Nominal Cfm
Diameter (in.)
(mm)
Motor Hp (Rpm)
3300
22
559
1/4 (1100)
3300
22
559
1/4 (1100)
3300
22
559
1/4 (1100)
3300
22
559
1/3 (1110)
3300
22
559
1/3 (1110)
3300
22
559
1/3 (1110)
OUTDOOR COIL
Rows...Fins/in.
Face Area (sq ft)
2...21
19.4
2...21
19.4
2...21
19.4
2...21
23.3
2...21
23.3
2...21
23.3
INDOOR COIL
Rows...Fins/in.
Face Area (sq ft)
3...17
5.7
3...17
5.7
3...17
5.7
4...17
5.7
4...17
5.7
4...17
5.7
INDOOR FAN
Nominal Airflow (Cfm)
Comfort
Variable based on Comfort Roll back (see User Interface instructions for more information).
Efficiency
1400
1400
1400
1750
1750
1750
Max
1600
1600
1600
2000
2000
2000
Furnace (gas ht.) airflow--- Low Stage
815
1215
1255
845
1215
1255
Furnace (gas ht.) airflow--- High Stage
1385
1885
1875
1300
1910
1920
Size (in.)
(mm)
11x10
279x254
11x10
279x254
11x10
279x254
11x10
279x254
11x10
279x254
11x10
279x254
Motor HP (RPM)
3/4
3/4
3/4
1
1
1
FURNACE SECTION*
Burner Orifice No. (Qty...Drill Size)
Natural Gas (Factory Installed)
Propane Gas
3...38
3...53
3...33
3...51
3...31
3...49
3...38
3...53
3...33
3...51
3...31
3...49
HIGH---PRESSURE SWITCH (psig)
Cut--- out
Reset (Auto)
670 ± 10
470 ± 25
HIGH---PRESSURE SWITCH 2 (psig)
(Compressor Solenoid)
Cut--- out
Reset (Auto)
565 ± 15
455 ± 15
LOSS---OF---CHARGE /
LOW---PRESSURE SWITCH
(Liquid Line) (psig)
Cut--- out
Reset (auto)
23 ± 5
55 ± 5
RETURN---AIR FILTERS Throwaway† (in.)
(mm)
24x36x1
610x914x25
*Based on altitude of 0 to 2000 ft (0 to 610 m).
{
Recommended filter sizes for field---installed air filter grilles mounted on the wall or ceiling of the conditioned structure. Required filter sizes shown are based on
the larger of the AHRI (Air Conditioning, Heating and Refrigeration Institute) rated cooling airflow or the heating airflow velocity of 300 ft/minute for throwaway
type or 450 ft/minute for high---capacity type. Air filter pressure drop for non---standard filters must not exceed 0.08 IN. W.C.
577D
--
--