Advantech PPC-140 User Manual
Page 154

136
PPC-120/140
User's Manual
STEP 3 - MODIFY CONFIG.SYS
MonitorMouse for OS/2 is installed by commands in CONFIG.SYS. Use
your system editor to make these changes. In general, the changes are as
follows:
1. Comment-out the existing DEVICE command(s) for your mouse.
2. Add a DEVICE command for the appropriate MonitorMouse for the
OS/2 touchscreen driver immediately after the commented-out
DEVICE commands(s).
3. Add a new DEVICE command for MOUSE.SYS.
The order of the DEVICE commands is important. Other changes may be
required depending on your hardware configuration and version of OS/2.
Serial Touchscreen Controller on PC Bus System
Change your CONFIG.SYS file as follows:
Rem C:/OS2\MOUSE.SYS {Flags}
Device=c:\elo\monmou01.sys port>, Device=c:\os2\mouse.sys stype=elomou$ {Flags - keep same as above} Where: is: 2300 for the IntelliTouch E281-2300 serial controller. 4002 for the IntelliTouch E281{A}-4002 serial controller. 2210 for the AccuTouch E271-2210 serial controller. 140 for the AccuTouch E271-140 serial controller. is: the number of the COM port where the serial output of the touchscreen matches the switch or jumper settings on the controller.
controller is connected.