Adcon A720 User Manual
Page 50

CHAPTER 4
Performing Advanced Functions
50
For RNS:
6789 PORT 80
6789 PORT 7/5/1999 18:34:22 0
#
C
OMMAND
RX
APPLIES
TO
A720, A720B, A723
D
ESCRIPTION
Switches the unit to permanent receive mode (for tuning pur-
poses).
P
ARAMETERS
None.
R
ETURNS
Nothing.
R
EMARKS
The system stops, and exits the command only when you press a
key. This command returns no message.
REMOTE
No.
E
XAMPLE
RX
193 RX 0
#
C
OMMAND
TX
APPLIES
TO
A720, A720B, A723
D
ESCRIPTION
Switches the unit to transmit mode (for tuning purposes).
P
ARAMETERS
None (sends an unmodulated carrier), 1 (sends a 1 kHz modulated
carrier), 0 (sends a 2 kHz modulated carrier) or 5 (sends a mixed 1 +
2 kHz modulated carrier).
R
ETURNS
Nothing.
R
EMARKS
The system stops, and exits the command only when you press a
key. This command returns no message.
REMOTE
No.
E
XAMPLE
TX
193 TX 0
#