CHAPTER 4

Using terminal commands

33

APPLIES

TO

A720, A720B, A723

D

ESCRIPTION

Sets/returns the input storing and sampling intervals.

P

ARAMETERS

storage represents the time (in seconds) elapsed between two
slots stored in the internal memory, while samples represents the
numbers of samples used to build the average that will be stored.

R

ETURNS

The interval and rate.

REMARKS

The default storage is 900 (15 minutes) and samples is 3 (3 sam-
ples per quarter of an hour).

REMOTE

Yes, SET only.

E

XAMPLE

SLOT 900 3
193 SLOT 0
#

SLOT
193 SLOT 900 3 0
#

Note: The A720B base station needs only the rate. For consis-

tency, however, it accepts both parameters and discards the
one it doesn’t need.

C

OMMAND

PMP

APPLIES

TO

A720, A720B, A723

D

ESCRIPTION

Sets/returns the node’s Power Management Parameters (switches
on/off the battery charge).

P

ARAMETERS

The lower (switch on) and the higher limit (switch off), both in volts
x 10. Standard Values are 65 (for 6.5 Volts) for switch on and 72 (for
7.2 Volts) for switch off.

R

ETURNS

The lower (switch off) and the higher limit (switch on), both in volts
x 10.

REMARKS

GET/SET.

REMOTE

Yes, SET only.

E

XAMPLE

PMP 65 72
193 PMP 0
#