Adcon A720 User Manual
Page 31

CHAPTER 4
Using terminal commands
31
C
OMMAND
FREQ
CAUTION
Do not change the frequency of your device without
reason. Apart from the fact that it may not communicate with the
network anymore, you may also violate the applicable radio-
communications laws in your country. Depending on the
destination country, some models may also return an error
message when trying to use this command.
APPLIES
TO
A720, A720B, A723
D
ESCRIPTION
Sets/returns the operating frequency.
P
ARAMETERS
The operating frequency and step (Hz), or none in the GET version.
R
ETURNS
The actual frequency and step, in Hz.
REMARKS
GET/SET.
REMOTE
Yes, SET only.
E
XAMPLE
FREQ 433925000 25000
193 FREQ 0
#
FREQ
193 FREQ 433925000 25000 0
#
C
OMMAND
RSSI
APPLIES
TO
A720, A720B, A723
D
ESCRIPTION
Sets/returns the Relative Signal Strength Indicator threshold at
which an RF receiver must wake up.
P
ARAMETERS
The threshold value. For the A720 family, it can take values from 0
to 255; it is typically factory set to 58. For the A723, it typically fac-
tory set to 42.
R
ETURNS
The instant RSSI value and the programmed threshold.
REMARKS
The factory default is set to 58 units. The RSSI threshold is used to
detect if any radio activity is on the channel. The value set must be
approximately 30% higher than the actual measured value when
no signal is present on the channel. To measure the actual value,
use the command
RSSI with no variables or parameters.