beautypg.com

Adcon A720 User Manual

Page 31

background image

CHAPTER 4

Using terminal commands

31

C

OMMAND

FREQ

CAUTION

Do not change the frequency of your device without

reason. Apart from the fact that it may not communicate with the
network anymore, you may also violate the applicable radio-
communications laws in your country. Depending on the
destination country, some models may also return an error
message when trying to use this command.

APPLIES

TO

A720, A720B, A723

D

ESCRIPTION

Sets/returns the operating frequency.

P

ARAMETERS

The operating frequency and step (Hz), or none in the GET version.

R

ETURNS

The actual frequency and step, in Hz.

REMARKS

GET/SET.

REMOTE

Yes, SET only.

E

XAMPLE

FREQ 433925000 25000
193 FREQ 0
#

FREQ
193 FREQ 433925000 25000 0
#

C

OMMAND

RSSI

APPLIES

TO

A720, A720B, A723

D

ESCRIPTION

Sets/returns the Relative Signal Strength Indicator threshold at
which an RF receiver must wake up.

P

ARAMETERS

The threshold value. For the A720 family, it can take values from 0
to 255; it is typically factory set to 58. For the A723, it typically fac-
tory set to 42.

R

ETURNS

The instant RSSI value and the programmed threshold.

REMARKS

The factory default is set to 58 units. The RSSI threshold is used to
detect if any radio activity is on the channel. The value set must be
approximately 30% higher than the actual measured value when
no signal is present on the channel. To measure the actual value,
use the command

RSSI with no variables or parameters.

This manual is related to the following products: