Adcon A720 User Manual
Page 40

CHAPTER 4
Performing Advanced Functions
40
30 4 1999 14 54 55 14 38 255 255 77 0 0 89 156 126
20 0 0 0 0
3185 0
#
Notice that if you need to get data that is not the last (newest) slot
remotely from a device, the ID must be supplied twice. If you need
to get the last slot stored, you can ignore the ID and the date/time
parameters:
8300 DATA
8300 DATA
13 5 1999 19 26 36 14 38 255 255 79 0 0 87 148 149
15 0 0 0 0
3138 0
C
OMMAND
IMME
APPLIES
TO
A723
D
ESCRIPTION
Returns immediate data.
P
ARAMETERS
None.
R
ETURNS
A formatted string representing the data sampled on the input
ports.
R
EMARKS
GET only. The answer to this command is delayed with the
SST
SST” on page 34). The values represent the normal
DATA frame values but formatted for easy human identification.
REMOTE
No.
E
XAMPLE
IMME
16816 IMME 30 8 2001 16 15 06 13 39 0 0 127
0 0 95
0 0 0 0 0 0
2350 0
#
C
OMMAND
ROUTE
APPLIES
TO
A723
D
ESCRIPTION
Updates a routing table than will be used for remote commands
(e.g.
DATA, INFO, etc.).