CHAPTER 4
Using terminal commands
43
— 4 for A733
— 5 for A723
— 6 for A440
•
slot and samples are the actual values programmed by
means of the
SLOT command
•
po (A723 only) is the relative output power
•
err_level is the error value; 0 means no error
R
EMARKS
GET only.
REMOTE
Yes, GET only. The A720B and A723 can issue the command both
remotely and locally, while the A720 can issue the command only
locally.
E
XAMPLE
INFO
193 INFO 255 0 18/4/1999 21:5:11 1.3 0 0 0 91 72
40 1:46 58 65 72 3 900 0 0
#
C
OMMAND
ANLG
A
PPLIES
TO
A723
D
ESCRIPTION
Sets/returns various parameters of the analog subsystem (e. g. the
sampling/averaging method used for individual data aquisition
channels).
P
ARAMETERS
A control byte specifying the command and the analog input chan-
nel number the command is acting on:
Figure 13. The ANLG Control Byte Layout.
Some commands may also require one or two additional 16 bit
parameters representing threshold values.
•
The Channel Number selects the analog channel that will be
affected by the command. For the A723 device, only 0000 to
0101 are accepted (only 6 analog channels are available).
Command Code
Channel Number