Adcon A720 User Manual
Page 34

CHAPTER 4
Performing Advanced Functions
34
PMP
193 PMP 65 72 0
#
C
OMMAND
CM
APPLIES
TO
A723
D
ESCRIPTION
Sets/returns the A720 compatibility mode.
P
ARAMETERS
0 means A723 native mode while 1 switches the unit in A720 com-
patible mode. In this mode, although the device presents itself as
an A723 (when issuing the
INFO command), it will return the frame
type 38 when asked for
DATA (see also “DATA” on page 36). This
mode is useful when the A723 device is used with the A720B base
station or with an addVANTAGE 3.35 software (addVANTAGE 3.4
and later recognizes an A723 in its native mode).
There is also an additional compatibility mode (
CM 2) that forces
the A723 to respond with an A720 compatible answer to the
INFO
command. This mode is not recommended for normal use.
By default the A723 devices are delivered in native mode (
CM is 0).
R
ETURNS
The current mode.
REMARKS
GET/SET.
REMOTE
No.
E
XAMPLE
CM 1
193 cm 0
#
CM
193 CM 1 0
#
C
OMMAND
SST
APPLIES
TO
A723
D
ESCRIPTION
Sets/returns Sensor Sampling Time. This is the delay allowed for
the sensors to settle after applying them power and until they are
sampled.
P
ARAMETERS
The settling time in seconds.