beautypg.com

Adcon A720 User Manual

Page 34

background image

CHAPTER 4

Performing Advanced Functions

34

PMP
193 PMP 65 72 0
#

C

OMMAND

CM

APPLIES

TO

A723

D

ESCRIPTION

Sets/returns the A720 compatibility mode.

P

ARAMETERS

0 means A723 native mode while 1 switches the unit in A720 com-
patible mode. In this mode, although the device presents itself as
an A723 (when issuing the

INFO command), it will return the frame

type 38 when asked for

DATA (see also “DATA” on page 36). This

mode is useful when the A723 device is used with the A720B base
station or with an addVANTAGE 3.35 software (addVANTAGE 3.4
and later recognizes an A723 in its native mode).

There is also an additional compatibility mode (

CM 2) that forces

the A723 to respond with an A720 compatible answer to the

INFO

command. This mode is not recommended for normal use.

By default the A723 devices are delivered in native mode (

CM is 0).

R

ETURNS

The current mode.

REMARKS

GET/SET.

REMOTE

No.

E

XAMPLE

CM 1
193 cm 0
#

CM
193 CM 1 0
#

C

OMMAND

SST

APPLIES

TO

A723

D

ESCRIPTION

Sets/returns Sensor Sampling Time. This is the delay allowed for
the sensors to settle after applying them power and until they are
sampled.

P

ARAMETERS

The settling time in seconds.