Error message of “calibration” is garbled – Konica Minolta bizhub PRESS C1060 User Manual
Page 4
4
When a merged mixed job is opened in Fiery Impose, the display of
the form size is incorrect
When a merged mixed job of different-sized (A3 and A4) documents is opened in Fiery
Impose, the display of the size of the form is not fixed to the size of the head page. Change the
paper size from A3 to A4 when you open Fiery Impose.
When multiple jobs are imported to the Held Queue in a group, the
job order is not cared
Use a mouse to select multiple jobs and import into the correct order in the Held Queue.
Output image of body pages from a booklet rotates 90 degrees after
printing a Microsoft Word document
In Command WorkStation, in the Driver properties of a Word document, if the job has either
Left or Top binding for Short Edge Feed (SEF) prints, or 1-up Perfect binding specified, the
output image of body pages from a booklet is rotated 90 degrees after printing. The image
rotation error does not occur with standard size or custom LEF documents. Use standard sizes
if the rotation error occurs with the custom sizes and top binding specified.
Printing a document as a booklet or as a 2-up print, with 1-byte or
2-byte TrueType font from a PS file into a PDF document, sometimes
results in garbled text output
Some 1-byte or 2-byte TrueType fonts cannot be embedded when you create a PDF from a PS
file. Print the document to PDF as a 1-up print for correct output.
Fiery Color Server hangs temporarily when it loads 500 paper profiles
from the printer
The Fiery Color Server may take a while to load all of the paper profiles that are imported
from the printer when you open Paper Catalog or Job Properties. Wait until all of the profiles
have been imported. If Command WorkStation becomes unresponsive, close and then restart
Command WorkStation and try again.
Error message of “Calibration” is garbled
Calibration does not support multiple users. A error message sometimes displays garbled text
at random instances.
Command WorkStation hangs on a client computer after rebooting the
Fiery Color Server
If you try to reconnect to the Fiery Color Server, Command WorkStation may become
unresponsive. Use Task Manager to close Command WorkStation, and then try to reconnect
again.