THe HeATeR muST NoT Be LoCATeD iN AN AReA WHeRe iT

WiLL Be SuBJeCT To fReeZiNG.
LoCATe iT NeAR A fLooR DRAiN. THe HeATeR SHouLD Be

LoCATeD iN AN AReA WHeRe LeAKAGe fRom HeATeR oR

CoNNeCTioNS WiLL NoT ReSuLT iN DAmAGe To ADJACeNT

AReA oR To LoWeR fLooRS of THe STRuCTuRe.
WHeN SuCH LoCATioNS CANNoT Be AVoiDeD, A SuiTABLe

DRAiN PAN SHouLD Be iNSTALLeD uNDeR HeATeR. Such

pans should be fabricated with sides at least 2” deep, with length

and width at least 2” greater than diameter of heater and must be

piped to an adequate drain. Pan must not restrict combustion air flow.

clearances

This water heater is approved for installation on combustible

flooring (with NSf leg kit #9003425205) in an alcove when

minimum clearance from any combustion construction are followed

as indicated in figure 6 and Table 4.
in all installations the minimum combustible clearances from vent piping

shall be 6” (152mm). Vent piping passing through a combustible wall

or ceiling must be a continuous run (no joints) and retain 6”

(152mm) clearance unless an approved reducing thimble is used.
A service clearance of 24” (610mm) should be maintained from

serviceable parts, such as relief valves, flue baffles, thermostats,

cleanout openings or drain valves.
The units are approved for installation with side, rear and ceiling

clearances as indicated below:
taBle 4.

minimum clearances to comBustiBles in inches (mm)

model

“a” right side “B” left side

“c” Back

“d” ceiling

BCG3 70T120 5NoX

2” 51 mm

2” 51 mm

2” 51 mm

12” 305 mm

BCG3 80T150 6NoX

2” 51 mm

2” 51 mm

2” 51 mm

12” 305 mm

BCG3 100T180 6NoX

2” 51 mm

2” 51 mm

2” 51 mm

12” 305 mm

BCG3 95T199 6NoX

2” 51 mm

2” 51 mm

2” 51 mm

12” 305 mm

BCG3 100T199 6NoX

2” 51 mm

2” 51 mm

2” 51 mm

12” 305 mm

A/BCG3 100T200 6NoX

2” 51 mm

2” 51 mm

2” 51 mm

12” 305 mm

A/BCG3 100T250 6NoX

2” 51 mm

2” 51 mm

2” 51 mm

12” 305 mm

A/BCG3 100T275 6NoX

2” 51 mm

2” 51 mm

2” 51 mm

12” 305 mm

A/BCG3 85T310 6NoX

6” 152 mm

6” 152 mm

6” 152 mm

12” 305 mm

A/BCG3 85T366 6NoX

6” 152 mm

6” 152 mm

6” 152 mm

12” 305 mm

A/BCG3 85T390 6NoX

3” 76 mm

3” 76 mm

3” 76 mm

12” 305 mm

taBle 5.

minimum clearances to non-comBustiBle construction

model

“a” right side “B” left side

“c” Back

“d” ceiling

BCG3 70T120 5NoX

0” 0 mm

0” 0 mm

0” 0 mm

12” 305 mm

BCG3 80T150 6NoX

0” 0 mm

0” 0 mm

0” 0 mm

12” 305 mm

BCG3 100T180 6NoX

0” 0 mm

0” 0 mm

0” 0 mm

12” 305 mm

BCG3 95T199 6NoX

2” 51 mm

2” 51 mm

2” 51 mm

12” 305 mm

BCG3 100T199 6NoX

0” 0 mm

0” 0 mm

0” 0 mm

12” 305 mm

A/BCG3 100T200 6NoX

0” 0 mm

0” 0 mm

0” 0 mm

12” 305 mm

A/BCG3 100T250 6NoX

0” 0 mm

0” 0 mm

0” 0 mm

12” 305 mm

A/BCG3 100T275 6NoX

0” 0 mm

0” 0 mm

0” 0 mm

12” 305 mm

A/BCG3 85T310 6NoX

3” 76 mm

3” 76 mm

3” 76 mm

12” 305 mm

A/BCG3 85T366 6NoX

0” 0 mm

0” 0 mm

0” 0 mm

12” 305 mm

A/BCG3 85T390 6NoX

0” 0 mm

0” 0 mm

0” 0 mm

12” 305 mm

locating the water heater

Property Damage Hazard

All water heaters eventually leak.

Do not install without adequate drainage.

CAUTION

When installing the heater, consideration must be given to proper

location. Location selected should be as close to the stack or chimney

as practicable, with adequate air supply and as centralized with the

piping system as possible.

Fire or Explosion Hazard

Read instruction manual before

installing, using or servicing

water heater.

Avoid all ignition sources if you smell gas.

Do not store or use gasoline or other flammable vapors and

liquids in the vicinity of this or any other appliance.

Use only the gas shown on the water heater rating label.

Keep ignition sources away from faucets after extended

periods of non-use.

Maintain required clearances to combustibles.

Do not expose water heater controls to excessive gas

pressure.

THeRe iS A RiSK iN uSiNG fueL BuRNiNG APPLiANCeS SuCH

as Gas WaTER HEaTERs IN RooMs, GaRaGEs oR oTHER

aREas WHERE GasolINE, oTHER FlaMMaBlE lIquIDs oR

eNGiNe DRiVeN equiPmeNT oR VeHiCLeS ARe SToReD,

oPeRATeD oR RePAiReD. fLAmmABLe VAPoRS ARe HeAVY

aND TRaVEl aloNG THE FlooR aND MaY BE IGNITED BY THE

HeATeR’S iGNiTeR oR mAiN BuRNeR fLAmeS CAuSiNG fiRe

oR eXPLoSioN. Some LoCAL CoDeS PeRmiT oPeRATioN of

GAS APPLiANCeS iN SuCH AReAS if THeY ARe iNSTALLeD 18”

oR moRe ABoVe THe fLooR. THiS mAY ReDuCe THe RiSK if

LoCATioN iN SuCH AN AReA CANNoT Be AVoiDeD.
Do NoT iNSTALL THiS WATeR HeATeR DiReCTLY oN A

CARPeTeD fLooR. A fiRe HAZARD mAY ReSuLT. instead the

water heater must be placed on a metal or wood panel extending

beyond the full width and depth by at least 3 inches in any direction.

if the heater is installed in a carpeted alcove, the entire floor shall

be covered by the panel. Also, see the DRAiNiNG requirements in

mAiNTeNANCe Section.
THe HeATeR SHALL Be LoCATeD oR PRoTeCTeD So iT iS NoT

SuBJeCT To PHYSiCAL DAmAGe BY A moViNG VeHiCLe.
fLAmmABLe iTemS, PReSSuRiZeD CoNTAiNeRS oR ANY oTHeR

PoTeNTiAL fiRe HAZARDouS ARTiCLeS muST NeVeR Be PLACeD

oN oR ADJACeNT To THe HeATeR. oPeN CoNTAiNeRS oR

FlaMMaBlE MaTERIal sHoulD NoT BE sToRED oR usED

iN THe SAme Room WiTH THe HeATeR.

installation considerations