Breathing Hazard - Carbon Monoxide Gas

Breathing carbon monoxide can cause brain damage or

death. Always read and understand instruction manual.

Under no circumstances should

the input exceed the rate shown

on the water heater’s rating label.

Overfiring could result in damage to

the water heater and sooting.

Gas and carbon monoxide detectors

are available.

INsTallaTIoNs aBoVE 2000 FEET (610 METERs) REquIRE

RePLACemeNT of BuRNeR oRifiCeS iN ACCoRDANCe

WiTH CuRReNT eDiTioN of THe NATioNAL fueL GAS

CoDe (ANSi Z223.1). foR CANADiAN iNSTALLATioNS

CoNSuLT CANADiAN iNSTALLATioNS CoDe CAN/CSA

B149.1. fAiLuRe To RePLACe oRifiCeS WiLL ReSuLT

iN imPRoPeR AND iNeffiCieNT oPeRATioN of THe

APPLiANCe ReSuLTiNG iN THe PRoDuCTioN of

iNCReASeD LeVeLS of CARBoN moNoXiDe GAS iN

eXCeSS of SAfe LimiTS WHiCH CouLD ReSuLT iN

SeRiouS PeRSoNAL iNJuRY oR DeATH.

You should contact your gas supplier for any specific changes

which may be required in your area.

As elevation above sea level is increased, there is less oxygen

per cubic foot of air. Therefore, the heater input rate should be

reduced at high altitudes for satisfactory operation with the

reduced oxygen supply. failure to make this reduction would

result in an over firing of the heater causing sooting, poor

combustion and/or unsatisfactory heater performance.

Ratings specified by manufacturers for most appliances apply

for elevations up to 2000 feet (610m). for elevations above 2000

feet (610), ratings must be reduced at the rate of 4% for each

1000 feet (305m) above sea level. for example, if a heater is

rated at 78,000 Btuh (22.9 Kwh) at sea level, to rate the heater

at 4000 feet (1219m), you subtract 4 (once for each thousand

feet) x.04 (4% input reduction) x 78,000 (original rating) from the

original rating.

Therefore, to calculate the input rating at 4,000 feet (1219m):

4 x .04 x 78,000 = 12,480 Btuh (3.7 Kwh), 78,000 (22.9 Kwh) -

12,480 (3.7 Kwh) = 65,520 Btuh (19.2 Kwh). At 6000 feet (1829m)

the correct input rating should be 59,280 Btuh (17.4 Kwh).

Some circulating pumps are manufactured with sealed bearings

and do not require further lubrication. Some circulating pumps

must be periodically oiled. Refer to the pump manufacturer’s

instructions for lubrication requirements.

CIRCULATING PUMP WIRING DIAGRAM

STORAGE TANK OR BUILDING RECIRCULATION

FIELD SUPPLIED TEMPERATURE CONTROL

INSTALLED IN THE STORAGE TANK

OR CIRCULATING LOOP RETURN LINE

CIRC

PUMP

MOTOR

L1 HOT

L2 NEUTRAL

120 VAC

POWER

NOTE: USE SEPARATE 120 VAC POWER

SUPPLY FOR PUMP CIRCUIT. DO NOT

SHARE POWER WITH APPLIANCE AS THIS

MAY CAUSE ELECTRICAL LINE NOISE AND

LEAD TO ERRATIC CONTROL SYSTEM

OPERATION.

CIRCULATING PUMP WIRING DIAGRAM

DISHWASHER LOOP WITH TOGGLE SWITCH

FIELD SUPPLIED TEMPERATURE

CONTROL INSTALLED IN THE

CIRCULATING LOOP RETURN LINE

DISHWASHER

TOGGLE

SWITCH

CIRC

PUMP

MOTOR

L1 HOT

L2 NEUTRAL

120 VAC

POWER

NOTE: USE SEPARATE 120 VAC POWER

SUPPLY FOR PUMP CIRCUIT. DO NOT

SHARE POWER WITH APPLIANCE AS THIS

MAY CAUSE ELECTRICAL LINE NOISE AND

LEAD TO ERRATIC CONTROL SYSTEM

OPERATION.

figure 8.

CIRCULATING PUMP WIRING DIAGRAM

STORAGE TANK OR BUILDING RECIRCULATION

FIELD SUPPLIED TEMPERATURE CONTROL

INSTALLED IN THE STORAGE TANK

OR CIRCULATING LOOP RETURN LINE

CIRC

PUMP

MOTOR

L1 HOT

L2 NEUTRAL

120 VAC

POWER

NOTE: USE SEPARATE 120 VAC POWER

SUPPLY FOR PUMP CIRCUIT. DO NOT

SHARE POWER WITH APPLIANCE AS THIS

MAY CAUSE ELECTRICAL LINE NOISE AND

LEAD TO ERRATIC CONTROL SYSTEM

OPERATION.

CIRCULATING PUMP WIRING DIAGRAM

DISHWASHER LOOP WITH TOGGLE SWITCH

FIELD SUPPLIED TEMPERATURE

CONTROL INSTALLED IN THE

CIRCULATING LOOP RETURN LINE

DISHWASHER

TOGGLE

SWITCH

CIRC

PUMP

MOTOR

L1 HOT

L2 NEUTRAL

120 VAC

POWER

NOTE: USE SEPARATE 120 VAC POWER

SUPPLY FOR PUMP CIRCUIT. DO NOT

SHARE POWER WITH APPLIANCE AS THIS

MAY CAUSE ELECTRICAL LINE NOISE AND

LEAD TO ERRATIC CONTROL SYSTEM

OPERATION.

figure 9.

high altitude installations

Fire and Explosion Hazard

Gas and carbon monoxide detectors are

available.

Overfiring could result in fire or

explosion.

Under no circumstances should the

input exceed the rate shown on the

water heater’s rating label.