openings must be installed to provide fresh air for combustion,

ventilation and dilution in confined spaces. The required size for

the openings is dependent on the method used to provide fresh

air to the confined space AND the total Btu/hr input rating of all

appliances installed in the space.
exhaust fans
Where exhaust fans are installed, additional air shall be provided

to replace the exhausted air. When an exhaust fan is installed

in the same space with a water heater, sufficient openings to

provide fresh air must be provided that accommodate the

requirements for all appliances in the room and the exhaust fan.

undersized openings will cause air to be drawn into the room

through the water heater’s vent system causing poor combustion.

Sooting, serious damage to the water heater and the risk of fire

or explosion may result. it can also create a risk of asphyxiation.

louVers and grilles
The free areas of the fresh air openings in the instructions that

follow do not take in to account the presence of louvers, grilles or

screens in the openings.
The required size of openings for combustion, ventilation and

dilution air shall be based on the “net free area” of each opening.

Where the free area through a design of louver or grille or screen

is known, it shall be used in calculating the size of opening

required to provide the free area specified. Where the louver and

grille design and free area are not known, it shall be assumed

that wood louvers will have 25% free area and metal louvers and

grilles will have 75% free area. Non motorized louvers and grilles

shall be fixed in the open position.

Never obstruct the flow of ventilation air. if you have any doubts

or questions at all, call your gas supplier. failure to provide the

proper amount of combustion air can result in a fire or explosion

and cause property damage, serious bodily injury or death.

unconfined space

An unconfined Space is one whose volume iS NoT LeSS THAN

50 cubic feet per 1,000 Btu/hr (4.8 cubic meters per kW) of the

total input rating of all appliances installed in the space. Rooms

communicating directly with the space, in which the appliances

are installed, through openings not furnished with doors, are

considered a part of the unconfined space.
Makeup air requirements for the operation of exhaust fans,

kitchen ventilation systems, clothes dryers and fireplaces shall

also be considered in determining the adequacy of a space to

provide combustion, ventilation and dilution air.
unusually tight construction
in unconfined spaces in buildings, infiltration may be adequate to

provide air for combustion, ventilation and dilution of flue gases.

However, in buildings of unusually tight construction (for example,

weather stripping, heavily insulated, caulked, vapor barrier, etc.)

additional air must be provided using the methods described in

the Confined Space section that follows.

confined space

A Confined Space is one whose volume iS LeSS THAN 50 cubic

feet per 1,000 Btu/hr (4.8 cubic meters per kW) of the total input

rating of all appliances installed in the space.

Venting installation

Venting

THe iNSTRuCTioNS iN THiS SeCTioN oN VeNTiNG muST

Be foLLoWeD To AVoiD CHoKeD ComBuSTioN oR

ReCiRCuLATioN of fLue GASeS. SuCH CoNDiTioNS

CAuSe SooTiNG oR RiSKS of fiRe AND ASPHYXiATioN.
Heater must be protected from freezing downdrafts.
Remove all soot or other obstructions from the chimney that will

retard a free draft.
Type B venting is recommended with these heaters. for typical

venting application see TeCHNiCAL DATA VeNTiNG on pages

17 and 18.
This water heater must be vented in compliance with all local

codes, the current revision of the National fuel Gas Code (ANSi-

Z223.1) and with the Category i Venting Tables.
if any part of the vent system are exposed to ambient temperatures

below 40°f it must be insulated to prevent condensation.

• Do not connect the heater to a common vent or chimney with

solid fuel burning equipment. This practice is prohibited by

many local building codes as is the practice of venting gas

fired equipment to the duct work of ventilation systems.

figure 11.

figure 12.

• Where a separate vent connection is not available and the vent

pipe from the heater must be connected to a common vent with

an oil burning furnace, the vent pipe should enter the smaller

common vent or chimney at a point above the large vent pipe.