Connecting – Lenovo ThinkServer TS430 User Manual
Page 54
To connect the cables, do the following:
1. Do one of the following:
• For the ThinkServer RAID 500 Adapter, use one 700 mm (27.56 inches) mini-SAS to mini-SAS
signal cable. Connect the mini-SAS connector
1
to the port 0 on the RAID card. Then, connect
the mini-SAS connector
2
to the mini-SAS signal cable connector 1 on the 2.5-inch hot-swap
hard-disk-drive backplane.
• For the ThinkServer RAID 700 Adapter, use one 700 mm (27.56 inches) mini-SAS to mini-SAS signal
cable. Connect the mini-SAS connector
5
to the ports 3-0 on the RAID card. Then, connect
the mini-SAS connector
6
to the mini-SAS signal cable connector 1 on the 2.5-inch hot-swap
hard-disk-drive backplane.
2. If you have more than four 2.5-inch hard disk drives installed, do one of the following. Otherwise, go
to the next step.
• For the ThinkServer RAID 500 Adapter, use the other 700 mm (27.56 inches) mini-SAS to mini-SAS
signal cable. Connect the mini-SAS connector
5
to the port 1 on the RAID card. Then, connect
the mini-SAS connector
6
to the mini-SAS signal cable connector 2 on the 2.5-inch hot-swap
hard-disk-drive backplane.
• For the ThinkServer RAID 700 Adapter, use the other 700 mm (27.56 inches) mini-SAS to mini-SAS
signal cable. Connect the mini-SAS connector
1
to the ports 7-4 on the RAID card. Then, connect
the mini-SAS connector
2
to the mini-SAS signal cable connector 2 on the 2.5-inch hot-swap
hard-disk-drive backplane.
3. Use the 2-pin 200 mm (7.87 inches) RAID card to system board hard-disk-drive LED cable. Connect
one end
4
to the external connector on the RAID card and the other end
3
to the hard-disk-drive
LED connector on the system board.
Note: The location of the external connector on the RAID card differs depending on the type of RAID
card. For information about the RAID card connectors, see “RAID card” on page 33.
Figure 25. Connecting cables for models with up to eight 2.5-inch SAS hot-swap hard disk drives and one backplane
For connector location information about the RAID card, hot-swap hard-disk-drive backplane, and the
system board, refer to the related topics in “Locations” on page 13.
For information about connecting the appropriate power connector of the power supply to the backplane,
see “Hot-swap hard-disk-drive backplane” on page 35.
Connecting cables for models with up to four 3.5-inch hot-swap hard disk drives and one backplane
For server models with up to four 3.5-inch SATA hot-swap hard disk drives and one backplane, you can
connect the cables in one of the following ways:
42
ThinkServer TS430 User Guide