XSz 8 ... XSz 50

Spare Parts

Series

Model (G-thread)

Model (NPT-thread)

Spare parts kits

Spare valve without base

XSz 8

24928063053

24928053053

0101534

2493805

XSz 10

24929323053

24929333053

0110641

2493930

XSz 20

24930320201

0110649

2494030

XSz 20

24930330201

0110649

2494030

XSz 32

24931050801

24931070801

0558631

2494130

XSz 32

24931060801

24931180801

0558631

2494131

XSz 50

24932300801

24932200801

0542576

XSz 50

24932310801

24932180801

0542576

Solenoids de-energized:
A port is exhausted. P port is
closed, no connection from P
to A. No residual pressure on
port A as port A is freely
exhausted through port R.
No acting pressure on port A.

Solenoids energized:
Pilots are synchronously
energised. Connection from
port P to A. Working pressure
on A. No passage from P to R.
Dynamic self monitoring of
both pilot systems, checking
each other at each cycle for
proper functioning.

Malfunction:
Pilots non-synchronously
energised. Dynamic monitor
notices failure operation and
prevents the pistons from
giving connection from P to A.
Synchronously port A exhausts
through R. No residual pressure
remains in the system since P and A
are not connected. The pilot line has
lost the pressure and is locked.

3 (R)

2 (A)

3 (R)

1 (P)

1 (P)

1 (P)

2 (A)

3 (R)

2 (A)

1 (P) = Air pressure port / 2 (A) = Power port (clutch / brake) / 3 (R) = Exhaust
Norgren Herion XSz Safety valves comply with the Category IV of DIN EN ISO 13849-1, if the operating system has been designed and realised according to Category IV.