Xsz 8 ... xsz 50, Spare parts – Norgren XSZ Series User Manual
Page 3
Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document. © 2014 Norgren GmbH
10/14
2002-5313h
N/en 5.14.100.03
XSz 8 ... XSz 50
Spare Parts
Series
Model (G-thread)
Model (NPT-thread)
Spare parts kits
Spare valve without base
XSz 8
24928063053
24928053053
0101534
2493805
XSz 10
24929323053
24929333053
0110641
2493930
XSz 20
24930320201
—
0110649
2494030
XSz 20
—
24930330201
0110649
2494030
XSz 32
24931050801
24931070801
0558631
2494130
XSz 32
24931060801
24931180801
0558631
2494131
XSz 50
24932300801
24932200801
0542576
—
XSz 50
24932310801
24932180801
0542576
—
Solenoids de-energized:
A port is exhausted. P port is
closed, no connection from P
to A. No residual pressure on
port A as port A is freely
exhausted through port R.
No acting pressure on port A.
Solenoids energized:
Pilots are synchronously
energised. Connection from
port P to A. Working pressure
on A. No passage from P to R.
Dynamic self monitoring of
both pilot systems, checking
each other at each cycle for
proper functioning.
Malfunction:
Pilots non-synchronously
energised. Dynamic monitor
notices failure operation and
prevents the pistons from
giving connection from P to A.
Synchronously port A exhausts
through R. No residual pressure
remains in the system since P and A
are not connected. The pilot line has
lost the pressure and is locked.
3 (R)
2 (A)
3 (R)
1 (P)
1 (P)
1 (P)
2 (A)
3 (R)
2 (A)
1 (P) = Air pressure port / 2 (A) = Power port (clutch / brake) / 3 (R) = Exhaust
Norgren Herion XSz Safety valves comply with the Category IV of DIN EN ISO 13849-1, if the operating system has been designed and realised according to Category IV.