If you are unable to get your scale working normally again, please follow the warranty instructions that
came with your Durascale to obtain a free replacement unit.
For advanced user repair of Durascale V2 ONLY:
The Version 2 has a round sticker on the bottom with 'QC Pass'
The problem of the scale showing “A.ch.Er”; or display “
-----
” when the weight on pan is less 50g) may be
solved by following method:
1. Prepare a small screwdriver, a fine-point tweezer;
2. Lightly move away the QC paster on the back of the scale using the tweezer; now you will see an
adjustable resistor from the hole on the scale back shell;
3. When the scale is off, press and hold down “ON/OFF” key , then press down “UNIT” key until “Hld.oN”
or “Hld.oF” is displayed;
4. Press “Pcs” key, the scale will display inner code or “A.ch.Er”;
5. Move away any weight on the scale; screw the screwdriver very slowly to adjust the resistor until
displayed inner code is in the range of 2000 to 8000;
6. Turn off the scale and put the QC sticker back onto the scale cover;
7. Re-calibrate the scale according to the user manual.
Durascale 2006 & 2007 Model Instructions:
AUTO TURN OFF&AUTO BACKLIGHT
Begin with the power OFF. Press and hold Pcs and ON/OFF toturn on the scale, the display will show
“OFF 0”(disabled) or “OFF 1” (automatic turn off after keep stable for 2 minutes) or “OFF 2”(automatic
turn off after no weighing for 5 minutes), select the auto turn off time by pressUNIT. Now confirm your
selection by pressingTARE. Now the display will show “BL 0”(backlight turn off is disabled) or “BL 1”(auto
backlight will turn off after about 10 seconds) or“BL 2” (auto backlight-off after about 20 seconds),
select auto backlight time by pressingUNIT , confirm it by pressing TARE . The scale will return to active
weighing.
(Advanced users only) CALIBRATION
IMPORTANT: This scale was professionally factory calibrated before shipment. It does NOT need to be
recalibrated before use and will not usually require calibration during its lifetime. However some
advanced users who seek optimum accuracy may wish to calibrate the scale periodically to maintain