beautypg.com

MyWeigh DuraScale User Manual

Page 4

background image

2) Press ‘TARE’, the ‘0’ in ‘CAL-0’ will flash;

3) When ‘CAL-F’ shows on the display, Place the 50gram calibration weight on the weighing platform

4) Press ‘TARE’, the ‘F’ in ‘CAL-F’ will flash ;

5) When ‘CAL-0’ appears on the display, remove the 50gram weight from the platform

6) Press ‘TARE’ , the ‘0’ in ‘CAL-0’ will flash

When the calibration is finished, the scale will automatically turn off/reset

NOTE: if after calibration your scale does not read accurately, this indicates

calibration error and the calibration process should be repeated more slowly.

Please calibrate on a very stable flat surface

DURASCALE 100 Easy Calibration:

There are two models of the Durascale 100. The instructions below are for each model so if you're not
sure - try both sets of instructions to see which one will work for your scale.

(Older D-100) Easy Calibration:
*Start with the scale powered off and nothing on the weighing platform.
1) press and hold both the‘ON/OFF’ and ‘TARE’ keys until ‘CAL-0’ appears on the display
2) Press ‘TARE’, the ‘0’ in ‘CAL-0’ will flash;
3) When ‘CAL-50’ shows on the display, Place a 50g calibration
weight on the platform and press 'TARE', the'50' in 'CAL-50' will flash;
4) When 'CAL-F' shows on the display, Place another 50g calibration
on the platform and press 'TARE' , the 'F' in 'CAL-F' will flash ;
5) When 'CAL-0' appears , remove all weights from the platform and
then press ‘TARE’ , the ‘0’ in ‘CAL-0’ will flash;
When the calibration is finished, the scale will automatically turn
off/reset
NOTE: if after calibration your scale does not read accurately, this indicates
calibration error and the calibration process should be repeated more slowly.
Please calibrate on a very stable flat surface

(Newer D-100) Easy Calibration:
*Start with the scale powered ON and nothing on the weighing platform.
1) press and hold ‘TARE’ until ‘CAL-0’ shows on the display
2) Press ‘TARE’, the ‘0’ in ‘CAL-0’ will flash;
3) When ‘CAL-F’ shows on the display, Place the 100gram calibration weight on the weighing platform
4) Press ‘TARE’, the ‘F’ in ‘CAL-F’ will flash ;
5) When ‘CAL-0’ appears on the display, remove the 100gram weight from the platform