Intel ICH10R SATA RAID

A RAID 1, RAID 5 or RAID 10 volume is reported as degraded when one of its hard
drive members fails or is temporarily disconnected, and data mirroring is lost. As a
result, the system can only utilize the remaining functional hard drive member. To re-
establish data mirroring and restore data redundancy, refer to the procedure below
that corresponds to the current situation.

Missing Hard Drive Member

1. Make sure the system is powered off.
2. Reconnect the hard drive.
3. Reboot the system to W indows; the rebuild will occur automatically.

Failed Hard Drive Member

1. Make sure the system is powered off.
2. Replace the failed hard drive with a new one that is of equal or greater

capacity.

3. Reboot the system to Intel RAID Option ROM by press and keys

simultaneously during the Power-On Self Test (POST).

Degraded RAID Array

4. Select the port of the destination disk for rebuilding, and then press ENTER.