Red' jumper dispense control, Fig 2a, Ids industrial dispenser instructions – FMI IDS User Manual
Page 4: Dispense switches, Dispense / start
IN-IDS-08
4
OPEN
1
2
4
12
8
11
10
9
'RED' Jumper
Dispense control
switchboard
Dispense
Switches
64
0
320 160 80 40 20 10
OFF
SPEED[RPM]
OFF
FL
U
ID METERIN
G
IN
C.
PC
B 30055
4
P
/N 200293
2
7 6 5 4 3 2 1
#200293
11 10 9
1
0
1
0
1
0
1
1
2
3
4
5
6
7
0
1
0
0
0
1
0
0
0
0
1
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0
1
0
0
0
0
1
1
1
9 10 11
9 10 11
Dispense /
start
Red Jumper
Location
Dispense
switch
0 = OFF
1 = ON
Red Jumper and Switch Settings / Dispense
Dispense Matrix
Fig 2A
2.1 Dispense Mode:
The IDS comes factory set for one dispense revolution** per signal at 320 rpm* Dispense start actuation
is handled by pins 6 (YELLOW) and return pin 7 (WHITE) of the external connector, P1. The minimum
signal input time that this function can respond to is .030 milliseconds (0.020 sec) to a maximum of 100
milliseconds, or less than the time it takes to make one revolution.
You can, have up to seven shots per signal if desired. The number of shots per Start signal is set by
switches 9, 10, 11 and Red Jumper on Switchboard # 200293. See Matrix below (Figure 2A) **( FMI has
determined that 320 RPM is best speed for a single revolution dispense, this may vary depending on the
hydraulics of your system.)
IDS INDUSTRIAL DISPENSER
INSTRUCTIONS