CDB5532U

DS807DB1

7

2.2.1.2

Window Menu

After the user selects the appropriate setup, the Window option becomes available in the Start-up window.
The Window pull-down has three options: Start-Up Window, Setup Window, and Data Collection Window.

2.2.2

Setup Window

The Setup window allows the user to access the internal registers of the CS5532. See Figure 5.

Figure 2. CDB5532U Setup Window

In the Setup window, all of the ADC’s registers are displayed as hexadecimal values. The configuration
register’s settings are also defined in this window.

Update Registers: The Update Registers button will read all the register values from the CS5532 and
update the hexadecimal values displayed on the screen. It is a good idea to press the Update Registers
button when entering the Setup window, or after modifying any registers to reflect the current status of the
part.

Reset Serial Port: When this button is selected, the software will send the synchronization sequence dis-
cussed in the CS5532 datasheet to the ADC. This sequence brings the CS5532’s serial port back to the
command mode, but does not reset any of the registers in the part.

Reset Part: When this button is selected, a ‘1’ is written to the RS bit in the configuration register to reset
the part. After a reset, the registers will all return to their default values as discussed in the CS5532
datasheet.