5 mode control (modes) – address: 16, Cs5464 – Cirrus Logic CS5464 User Manual
Page 34

CS5464
34
DS682F3
8.3.5 Mode Control (Modes)
–
Address: 16
Default = 0
Ichan
Chooses an energy channel to drive the E
PULSE
, S
PULSE
, and Q
PULSE
registers.
0 = Pulse registers driven by energy channel 1.
1 = Pulse registers driven by energy channel 2.
VFIX
Use internal RMS voltage reference instead of voltage input for average active power.
0 = Use voltage input.
1 = Use Internal RMS voltage reference, VF
RMS.
IvsE
Use I
RMS
results instead of P
AVG
for energy channel selection
0 = Use P1
AVG
and P2
AVG
instead of I1
RMS
and I2
RMS.
1 = Use I1
RMS
and I2
RMS
instead of P1
AVG
and P2
AVG.
E1MODE[1:0]
E1, E2, and E3 alternate Output Mode (when enabled by E2MODE)
00 = E1, E2 = P1
AVG
, P2
AVG
01 = E1, E2 = S1, S2
10 = E1, E2 = Q1
AVG
, Q2
AVG
11 = E1, E2 = Q1
WB
, Q2
WB
Ihold
Suspends automatic channel selection.
0 = Channel selected automatically by magnitude compare.
1 = Channel selected by application (host).
E2MODE[1:0]
E2 Output Mode
00 = Energy Sign
01 = Apparent Energy
10 = Channel In Use
11 = Enable E1MODE
VHPF2:IHPF2
High-pass Filter Enable for Energy Channel 2
00 = No Filter
01 = HPF on Current, PMF on Voltage
10 = HPF on Voltage, PMF on Current
11 = HPF on both Voltage and Current
VHPF1:IHPF1
High-pass Filter Enable for Energy Channel1
00 = No Filter
01 = HPF on Current, PMF on Voltage
10 = HPF on Voltage, PMF on Current
11 = HPF on both Voltage and Current
E3MODE[1:0]
E3 Output Mode (with E1MODE disabled)
00 = Reactive Energy (default)
01 = Power Fail Monitor
10 = Voltage Sign
11 = Apparent Energy
23
22
21
20
19
18
17
16
Ichan
VFIX
-
-
-
-
-
-
15
14
13
12
11
10
9
8
IvsE
E1MODE1
E1MODE0
Ihold
-
E2MODE1
E2MODE0
VHPF2
7
6
5
4
3
2
1
0
IHPF2
VHPF1
IHPF1
-
E3MODE1
E3MODE0
POS
AFC