2. CHARACTERISTICS AND SPECIFICATIONS
(Min/Max performance characteristics and specifications are guaranteed over the Specified Operating Conditions.
Typical specifications are derived from performance measurements at T
A
= 25 °C, VA_H = 12 V, VA = 3.3 V,
VD = 3.3 V.)
SPECIFIED OPERATING CONDITIONS
(GND = 0 V; all voltages with respect to ground.)
ABSOLUTE MAXIMUM RATINGS
(GND = 0 V; all voltages with respect to ground.)
Operation at or beyond these limits may result in permanent damage to the device. Normal operation is not guar-
anteed at these extremes.
Parameters
Symbol Min Typ
Max
Units
DC Power Supply
High Voltage Analog power
Low Voltage Analog power
Digital power
Interface power
V
A_H
V
A
V
D
V
L
8.55
3.13
3.13
1.7
12
3.3
3.3
3.3
12.6
3.47
3.47
3.47
V
V
V
V
Specified Temperature Range
-CZZ
-DZZ
T
A
T
A
-10
-40
-
-
70
85
°C
°C
Parameters
Symbol
Min
Max
Units
DC Power Supply
High Voltage Analog power
Low Voltage Analog power
Digital power
Interface power
V
A_H
V
A
V
D
V
L
-0.3
-0.3
-0.3
-0.3
14
3.63
3.63
3.63
V
V
V
V
Input Current, Any Pin Except Supplies
I
in
-
±10
mA
Digital Input Voltage
Digital Interface
V
IN-L
-0.3
V
L
+ 0.4
V
Ambient Operating Temperature (power applied)
T
A
-55
125
°C
Storage Temperature
T
stg
-65
150
°C