2. CHARACTERISTICS AND SPECIFICATIONS

(Min/Max performance characteristics and specifications are guaranteed over the Specified Operating Conditions.
Typical specifications are derived from performance measurements at T

A

= 25 °C, VA_H = 12 V, VA = 3.3 V,

VD = 3.3 V.)

SPECIFIED OPERATING CONDITIONS

(GND = 0 V; all voltages with respect to ground.)

ABSOLUTE MAXIMUM RATINGS

(GND = 0 V; all voltages with respect to ground.)

Operation at or beyond these limits may result in permanent damage to the device. Normal operation is not guar-
anteed at these extremes.

Parameters

Symbol Min Typ

Max

Units

DC Power Supply

High Voltage Analog power

Low Voltage Analog power

Digital power

Interface power

V

A_H

V

A

V

D

V

L

8.55
3.13
3.13

1.7

12

3.3
3.3
3.3

12.6
3.47
3.47
3.47

V
V
V
V

Specified Temperature Range

-CZZ
-DZZ

T

A

T

A

-10
-40

-
-

70
85

°C
°C

Parameters

Symbol

Min

Max

Units

DC Power Supply

High Voltage Analog power

Low Voltage Analog power

Digital power

Interface power

V

A_H

V

A

V

D

V

L

-0.3
-0.3
-0.3
-0.3

14

3.63
3.63
3.63

V
V
V
V

Input Current, Any Pin Except Supplies

I

in

-

±10

mA

Digital Input Voltage

Digital Interface

V

IN-L

-0.3

V

L

+ 0.4

V

Ambient Operating Temperature (power applied)

T

A

-55

125

°C

Storage Temperature

T

stg

-65

150

°C