SECTION 7: OPTIONAL HEATER ACCESSORIES

7.1 U-Tube Configuration

Heaters are approved for optional U-Tube
configurations.

The U-Tube may be installed in either a standard
horizontal position, a 45° position or in an opposite
45° position as shown

on Page 7, Figure 7 through

Figure 9. When using a U-Tube configuration, the
following additional rules must be adhered to:

• A minimum of 10' (3 m) on CTH3-80 and a mini-

mum of 15' (4.5 m) on CTH3-115/150/200 is
required between the burner and the U-Tube.

• The correct turbulator (

See Page 18, Figure 6.4)

must be installed in the last standard section of
tube.

• The burner must never be operated in a tilted

position.

• The heater must be properly supported at all loca-

tions.

See Page 24, Figure 18.

WARNING

Cut/Pinch Hazard

Wear protective gear during installation,
operation and service.

Edges are sharp.

Failure to follow these instructions can result
in injury.