NOTE: 1. All dimensions are from the surfaces of all tubes, couplings and elbows.
2. Clearances B, C and D can be reduced by 50% after 25' (7.5 m) of tubing downstream
from where the burner and burner tube connect.
FIGURE 4: ONE SIDE REFLECTOR
(inches)
(centimeters)
Model
A
B
C
D
A
B
C
D
CTH3-80
6
9
70
54
16
23
178
138
CTH3-115
6
9
83
65
16
23
211
166
CTH3-150
6
9
86
69
16
23
219
176
CTH3-200
8
9
88
73
21
23
224
186
A
C
D
B
FIGURE 5: TWO SIDE REFLECTORS
(inches)
(centimeters)
Model
A
B
C
D
A
B
C
D
CTH3-80
6
25
72
25
16
64
183
64
CTH3-115
6
32
84
32
16
82
214
82
CTH3-150
6
35
88
35
16
89
224
89
CTH3-200
8
40
91
40
21
102
232
102
A
C
D
B
FIGURE 6: 45
°
TILT REFLECTOR
(inches)
(centimeters)
Model
A
B
C
D
A
B
C
D
CTH3-80
8
8
66
60
21
21
168
153
CTH3-115
10
8
78
69
26
21
199
176
CTH3-150
12
8
84
74
31
21
214
188
CTH3-200
12
8
85
79
31
21
216
201