26800-90(K)

STANDARD DEVIATION

calculates the standard deviation

of samples from SLOC and stores the result in DLOC. #SAMP

defines the number of samples for MOVING type only.

BLOCK type adds new values with each instruction iteration.

When FLAG 1 is ON, the standard deviation is calculated. The

process begins again when FLAG 1 is OFF.

MOVING type keeps a list of every sample. After #SAMP

samples have been collected, the first standard deviation is

calculated. After that, a new standard deviation is calculated for

each new sample acquired. Each MOVING standard deviation

instruction automatically allocates the needed internal memory.

If memory limits are reached and PGM ERR HANDLE is set to

STOP, an error message will appear.

ANGLE types internally convert unit vector angles to Cartesian

values which are used for the actual calculation. Internal Car-

tesian standard deviations are converted back to angles for the

final result. MOVING ANGLE employs the Yamartino algorithm.

sloc=

Source location

dloc=

Destination location

type=

BLOCK, BLK ANGLE, MOVING, MOV ANGLE

#samp=

Number of samples (0001-1750)

WIND DIRECTION 0-540

converts 0-360° wind direction in

SLOC (degrees) to a 0-540° range stored in DLOC. When used

to produce an analog output, the 0-540° range helps prevent

chart "painting" or excessive zero-to-full-scale excursions when

the wind direction oscillates about the 0/360° transition.

sloc=

Source location (001-256)

dloc=

Destination location (001-256)

5.0 SERIAL COMMUNICATION

The 26800 includes two independent serial communication chan-

nels: COM1 and COM2. COM1 may be set to operate as either an

RS-232 or RS-485 port. Baud rates for either channel may be set

to any of several common values between 1200 and 230.4K baud.

Format is 8 bits data, 1 stop, no parity. No handshaking is used.

Either serial channel may be controlled by the USER PROGRAM

for input or output using INPUT SERIAL and SERIAL BUFFER

instructions.

The USB port is dedicated to communication with RMYComm, the

included Windows PC program used to manage setup parameters,

static screen text, the user program, and recorded data.

6.0 ERROR MESSAGES

When an error occurs during OPERATE MODE and PGM ERR

HANDLE is set to STOP, the 26800 generates an error message

and takes the user to the offending instructions with an option to

edit.

1 DIVIDE BY 0 ERROR IN INSTR N

Zero value in temporary storage instruction LOC used as a

divisor in this instruction.

2 INVALID ARGUMENT IN INSTR N

Serial input string is invalid or screen number in temporary

storage location is invalid.

3 BUFFER OVERRUN ERROR IN INSTR N

Auto-incrementing index for serial output has exceeded

64-character buffer length limit.

Declaration of Conformity

R. M. Young Company

2801 Aero Park Drive

Traverse City, MI 49686 USA

Model 26800 Meteorological Display

The undersigned declares on behalf of R. M. Young

Company that the above-referenced product conforms

with the provisions of:

Council Directive 2004/108/EC (December 15, 2004)

on Electromagnetic Compatibility;

David Poinsett

R & D Manager

4 END-IF WITHOUT IF ERROR IN INSTR N

Each END-IF must be preceded by a matching IF statement.

5 ELSE WITHOUT IF ERROR IN INSTRUCTION N

Each ELSE statement must be preceded by a matching IF

statement.

6 CORRUPT USER PROGRAM IN INSTR N

Reload the user program.

7 TIMEOUT IN INSTRUCTION N

Determine cause. Increase PGM INTERVAL and/or TIMEOUT

INTERVAL if needed.

8 UNKNOWN ERROR IN INSTRUCTION N

Review USER PROGRAM.

7.0 WARRANTY

This product is warranted to be free of defects in materials and

construction for a period of 12 months from date of initial purchase.

Liability is limited to repair or replacement of defective item. A copy

of the warranty policy may be obtained from R. M. Young Com-

pany.

8.0 CE COMPLIANCE

This product complies with European CE requirements for the

EMC Directive (see Declaration of Conformity below). Please

note that shielded cable and Model 26860 RF Suppression Kit (or

equivalent) must be used.