beautypg.com

Young Voltage & Current Interfaces 05631C User Manual

Young Sensors

background image

INSTRUCTION SHEET 05631C-90

REV: B051311

MODEL 05631C

WIND LINE DRIVER

SPECIFICATIONS

Wind Speed Input:

YOUNG Wind Monitor series of sensors

AC sine wave, Frequency proportional

to wind speed. 3 pulses per revolution.

Input sensitivity nom. 40 mV p-p

Wind Direction Input:

Analog voltage from azimuth

potentiometer. Regulated excitation

voltage is supplied from interface circuit

to potentiometer.

Wind Speed Output:

4 to 20 mA = 0-100 M/S

Wind Direction Output: 4 to 20 mA = 0 to 360°

Overall accuracy:

± 1% of full scale over temperature and

supply voltage range

Dimensions:

110 mm W x 75 mm H x 56 mm D

(4.3 in W x 2.9 in H x 2.2 in D)

Mounting:

U-bolt for vertical pipe

25-50mm (1-2 in) Diameter

Power Requirement:

12-30 VDC

Temperature Range:

-50 to 50°C (-58 to 122°F)

INTRODUCTION

The Wind Line Driver converts raw signals from the wind sensors to

proportional 4 to 20 mA current loop values. The Line Driver acts like

a variable resistance that draws 4 - 20 mA when powered with 12 to

30 VDC. Although it has only one PC board, the Line Driver contains

two completely independent circuits - one for wind speed and the

other for wind direction. See wiring diagram below.

IMPORTANT!

The Wind Line Driver provides a calibrated current signal

for wind speed and wind direction. Externally connected

devices should be reviewed for compatibility and correct

signal scaling.

Repairs should be attempted only by qualified service personnel.

Declaration of Conformity

R. M. Young Company

2801 Aero Park Drive

Traverse City, MI 49686 USA

Model 05631C Wind Line Driver

The undersigned hereby declares on behalf of R. M.

Young Company that the above-referenced product, to

which this declaration relates, is in conformity with the

provisions of:

Council Directive 2004/108/EC (December 15, 2004)

on Electromagnetic Compatibility

David Poinsett

R&D Manager

WARRANTY

This product is warranted to be free of defects in materials and

construction for a period of 12 months from date of initial purchase.

Liability is limited to repair or replacement of defective item. A copy

of the warranty policy may be obtained from R. M. Young Company.

CE COMPLIANCE

This product has been tested and shown to comply with European

CE requirements for the EMC Directive. Please note that shielded

cable must be used.

CALIBRATION FORMULAS

WIND SPEED vs

mA OUTPUT

m/s

=

( 6.250 x mA)-25

knots

=

(12.149 x mA)-48.6

mph

=

(13.980 x mA)-56

km/h

=

(22.500 x mA)-90

WIND DIRECTION vs

mA OUTPUT

DEGREES =

(22.5 x mA)-90

R. M. YOUNG COMPANY

2801 Aero Park Drive , Traverse City, Michigan 49686 U.S.A.

TEL (231) 946-3980 FAX (231) 946-4772 E-mail: [email protected]

This manual is related to the following products: