INTRODUCTION

The Multi-Plate Radiation Shield protects temperature and

relative humidity sensors from error-producing solar radiation

and precipitation. This shield relies on a combination of plate

geometry, material and natural ventilation to provide effective

shielding.

INSTALLATION

The Multi-Plate Radiation Shield is designed to be mounted on

a relatively flat open area. For best performance, the shield

should be placed in a location with the following characteristics:

- Good air circulation around shield.

- Away from large masses (asphalt, masts, solar panels)

especially metal items.

- Away from building exhaust vents, electrical machinery

and motors.

- Away from standing water, water fountains and

sprinklers.

MAINTENANCE

The Multi-Plate Radiation Shield requires no regular maintenance

in normal use. Dirt or dust accumulation on the plates and bracket

can be cleaned with soap and water.

Do not use solvents.

SPECIFICATIONS
Sensor Mounting:

Model 41003:

Universal adapter for sensors up to 16mm diameter.

Model 41003P-24:

A 24mm adapter for standard YOUNG sensors.

Model 41003P:

Custom sensor adapter that can be machined for

sensors up to 26mm diameter.

Radiation Error: 1080 W/m

2

intensity

0.4°C (0.7°F) RMS @ 3 m/s (6.7 mph)

0.7°C (1.3°F) RMS @ 2 m/s (4.5 mph)

1.5°C (2.7°F) RMS @ 1 m/s (2.2 mph)

Construction:

UV stabilized white thermoplastic plates.

Stainless Steel Plate Studs.

Aluminum mounting bracket, white powder coated.

Stainless steel U-bolt mounting clamp.

Dimensions:

13 cm (5.1 in) D x 27 cm (10.6 in) H

Mounting fits vertical pipe 25-50 mm (1-2 in) diameter

Weight:

Net wt 0.7 kg (1.6 lb)

Ship wt 1.4 kg (3.2 lb)

MODEL 41003

MULTI-PLATE RADIATION SHIELD

INSTRUCTION SHEET 41003-90

REV C012114