beautypg.com

Young Sensors Relative Humidity & Temperature Probes Models 41382LC2 User Manual

Young Sensors

background image

MODEL 41382LC2

RELATIVE HUMIDITY

/

TEMPERATURE PROBE

with CURRENT OUTPUTS

INSTRUCTION SHEET 41382LC2-90

REV B102613

R. M. YOUNG COMPANY

2801 Aero Park Drive , Traverse City, Michigan 49686 USA

TEL (231) 946-3980 FAX (231) 946-4772

I

NTRODUCTION

The Model 41382LC2 Relative Humidity/Temperature Probe

combines high accuracy humidity and temperature sensors in a

single probe. The output signal is 4-20 mA. RH range is 0-100%.

Temperature range is -50 to +50°C.

INSTALLATION

Install the probe in a naturally ventilated or fan aspirated radiation

shield. Mount probe and shield in a location with good air

circulation clear of large thermal masses (buildings, pavement,

solar panels, etc.), exhaust vents, electrical machinery and motors,

water fountains and sprinklers. Typical wiring diagrams appear on

next page.

MAINTENANCE

The probe provides years of service with minimal maintenance.

Humidity calibration, which may drift slightly with time, can be

checked or restored at the factory.

Periodically clean the humidity sensor filter when used in areas of

high dust or contamination (smokestacks, seawater, etc.) Soak in
clean water or use a mild soap solution. DO NOT USE SOLVENTS.

CE COMPLIANCE

This product complies with the European CE directive on EMC

compatibility. Shielded cable must be used.

WARRANTY

This product is warranted to be free of defects in materials

and construction for a period of 12 months from date of

initial purchase. Liability is limited to repair or replacement of

defective item. A copy of the warranty policy may be obtained

from R. M. Young Company.

SPECIFICATIONS

RELATIVE HUMIDITY:

Measuring range:

0-100% RH

Accuracy at 23°C:

±1%

Stability:

Better than ±1%RH per year

Response Time:

10 seconds (Without Filter)

Sensor type:

Rotronic Hygromer

TEMPERATURE:

Measuring Range:

-50 to +50°C

Accuracy at 23°C:

±0.3°C

Response Time:

10 seconds (Without Filter)

Sensor type:

Platinum RTD

W

Output signal:

4-20 mA

Power Required:

5-30 VDC, 46 mA max

Recommended Cable:

2 Pair shielded 22AWG, Young 18723

Recommended Shields:

Young Model 43502 Aspirated Radiation Shield

Young Model 41003P Multi-Plate Radiation Shield

Declaration of Conformity

R. M. Young Company

2801 Aero Park Drive

Traverse City, MI 49686 USA

Model 41382LC2 RH/Temp Probe

The undersigned hereby declares on behalf of R. M. Young

Company that the above-referenced product, to which this

declaration relates, is in conformity with the provisions of:

Council Directive 2004/108/EC (December 15, 2004)

on Electromagnetic Compatibility

David Poinsett

R&D Manager

7.4in

188mm

5.4in

136mm

.94in

24mm

2.5in

62mm

3.4in

86.5mm

FILTER