AVERAGING
When averaging is enabled, the front-panel AVG annunciator is
illuminated, and average wind speed and direction values are
displayed at intervals set by the Period (PEr) parameter. When
averaging is disabled, instantaneous wind values are displayed.
BRIGHTNESS
Adjust display brightness by pressing and holding the left BRIGHT
key for 1 second.
MAXIMUM or WIND DIRECTION DISPLAY
Either MAXIMUM WIND SPEED GUST or numerical WIND
DIRECTION appears during operation depending on Right Display
Window (dSP) parameter setting. Maximum gust may be reset
during normal operation by pressing and holding the RESET key
for 1 second.
REMOTE DISPLAYS
When set for any non-serial input, the Wind Tracker functions
as a master display source for other Wind Trackers which have
been configured for remote display with InP=SEr. The master
Wind Tracker must also be set for binary serial output (Out=bin).
MASTER: Sensor InP = any non-serial device, Out=bin
REMOTE: Sensor InP = SEr
Connect one Wind Tracker master to up to 16 remote displays
via the RS-485 terminals as shown in wiring diagrams. Remote
Wind Trackers display exactly the same information as the master
including alarm states. MAX RESET and all display features are
controlled by the master unit only. Brightness can be adjusted
independently at each Wind Tracker display.
VOLTAGE OUTPUTS
Calibrated voltage outputs for wind speed and direction are updated
16 times per second. Wind Speed 0-100 m/s = 0.00 to 5.00 VDC.
Wind Direction may be scaled for either 0-360 or 0-540 degrees =
0.00 to 5.00 VDC by setting the Direction (dir) parameter.
4-20 mA INPUTS
The Wind Tracker accepts 4-20 mA Line Driver inputs with either
0-50 m/s or 0-100 m/s scaling (Ldi and Ld2 input settings). Connect
as shown in wiring diagram. The back-panel switch labeled 4-20
mA must be in the UP position. 24VDC power is recommended
for most 4-20 mA installations.
POWER CONNECTIONS
The Wind Tracker operates from a 12 to 30 VDC power source.
Power may be connected via the coaxial jack or terminals. These
are internally wired in together so DO NOT CONNECT MORE
THAN ONE POWER SOURCE AT THE SAME TIME. See wiring
diagrams for examples.
ERROR MESSAGES
Ldi
Err
4-20 mA (line driver) signal is missing or outside
an acceptable range. Verify connections, signal,
and 4-20 mA switch in UP position.
SEr
Err
Unit set to receive RS-485 serial signal (inP=SEr
or 09), but no serial data detected. Verify serial
source is working. Verify connections.
Declaration of Conformity
R. M. Young Company
2801 Aero Park Drive
Traverse City, MI 49686 USA
Model 06201 Wind Tracker
The undersigned hereby declares on behalf of R. M.
Young Company that the above-referenced product, to
which this declaration relates, is in conformity with the
provisions of:
Council Directive 2004/108/EC (December 15, 2004)
on Electromagnetic Compatibility
David Poinsett
R&D Manager
SPECIFICATIONS
Size:
144 mm (5.65 in) x 144 mm (5.65 in) x 36 mm (1.4 in)
Panel Cutout: 138 mm (5.43 in) x 138 mm (5.43 in)
Sensors:
Wind Monitor (05), Wind Monitor-AQ (05A), Wind
Monitor-SE (09), Ultrasonic Anemometer (09),
Wind Monitor-JR (04), Wind Sentry (03), Wind
Monitor HD (Hd)
Accuracy:
±0.6% Full Scale
Serial I/O:
Proprietary binary I/O for master-remote display
or simple ASCII text output for external device:
ss.s ddd
ss.s windspeed (m/s)
ddd wind direction in degrees
RS-485 half-duplex, 9600 baud,
8-1-n, no handshaking
Other inputs: 4-20 mA (0-360 deg, Ldi 0-50 m/s, Ld2 0-100 m/s)
Other outputs: 0-5 VDC = 0-360° or 0-540°
0-5 VDC = 0-100 m/s
Alarm Relays: Normally Open contacts for WS and WD Contact
rating 24 VAC or 30 VDC maximum 5A resistive,
2A inductive maximum
Input Power: 12-30 VDC, 3.5 W
Weight:
1.0 lb (0.45 kg) without AC adapter
CE COMPLIANCE
This product complies with European CE EMC Directive.
Shielded cable must be used.
WARRANTY
The Wind Tracker is warranted to be free of defects in materials
and construction for a period of 12 months from date of purchase.
Coverage is limited to repair or replacement of defective unit.