7. Servicing, Maintenance, Cleaning, Repairing / 8. Storage

7. Servicing, Maintenance, Cleaning, Repairing

Always open isolating devices gently, never abruptly, since this may

generate sudden pressure surges that may damage the gauge.

Pressure instruments with an electrical output signal / electronic pressure

switch

require no maintenance and offer a long service life, if handled and

operated properly. If the zero point drifts, it means that the instrument has

been overloaded.

Clean the instrument with a moistened cloth. If badly soiled, moisten the

cloth thoroughly with soapy water.

Repairs should be only be carried out by the manufacturer or by appropri-

ately trained staff.

8. Storage

Before the system is stored, all traces of any medium

residue must be removed. This is particularly important,

if the media is a health hazard such as corrosive, toxic,

carcinogenic, radioactice, etc.

Before installation, in order to prevent damage to the pressure

instrument, the following points should be observed:

The pressure instrument should be left in its original packaging until

installation.

After taking the instrument out (e.g. for test), reuse the original

packaging material.

The storage temperature should not be less than -40 °C or more

than +90 °C

Avoid the following influences:

Direct sunlight or vicinity to hot objects

Mechanical vibration

Sot, steam, dust, humidity and corrosive gasses

Potentially explosive environment, inflammable atmospheres