beautypg.com

WIKA PGS07 User Manual

Page 7

background image

11349167.03 10/2011 GB/D/F/E

WIKA operating instructions intelliGAUGE / switchGAUGE

Contents of

tailpipe

Typically

Liquid media

Gaseous media

Liquid

Liquid

with

vapour

Vapour

only

Gas only

Wet gas

Liquid

gas con-

densate

Conden-

sate

Boiling

liquid

Liquefied

gas

Dry air

Moist air,

Flue gas

Steam

Pressure

instrument

higher than

tapping point
Pressure in-

strument lower

than tapping

point

7

GB

4. Installation and commissioning / 5. Measuring arrangements

If the pressure transmitter is positioned lower than the pressure test

connection, the tailpipe has to be rinsed thoroughly prior to fitting the gauge

to remove all foreign substances.
Once the pressure and electrical connections have been made, the trans-

mitter is ready for immediate use.
Before dismounting the pressure instrument the measuring element has to

be depressurized. Eventually the stress of the pipe has to be relieved.

Residual pressure medium remaining within the pressure

element may cause harm to men, facilities and environment.

Therefore sufficient precautionary measures have to be

taken.

Pressure connector

In accordance with the general technical regulations for pressure gauges

(e.g. EN 837-2 „Selection and installation recommendations for pressure

gauges“).

5. Measuring arrangements

Proven measuring arrangements for various types of media.

Installation using

a spanner

This manual is related to the following products: