Specifications – WIKA DPS40 User Manual
Page 9
![background image](/manuals/465701/9/background.png)
GB
WIKA operating instructions DELTA-plus, DELTA-comb and DELTA-switch
9
14093265.01 03/2014 GB/D/F/E
3. Specifications
Specifications
DELTA-switch model DPS40
Case diameter
100 mm
Differential pressure measuring
ranges
0 ... 0.25 to 0 ... 10 bar
Max. working pressure (stat.)
25 bar
Overpressure safety
Either side max. 25 bar
Permissible temperatures
Ambient: -10 ... +70 °C, medium: -10 ... +90 °C
Storage: -40 ... +70 °C
Ingress protection
IP 54 per EN 60529 / IEC 60529
Media chamber (wetted)
Aluminium, EN AC–Al Si9Cu3(Fe), black lacquered
Process connections (wetted)
2 x G 1/4 female, lower mount (LM), in-line, centre
distance 26 mm
Pressure elements (wetted)
Differential pressure: Compression springs from
stainless steel 1.4310 and separating diaphragm
from FPM/FKM (option: NBR)
Transmission parts (wetted)
Stainless steel 1.4301, 1.4305, 1.4310, FPM/FKM
(option: NBR)
Sealings (wetted)
FPM/FKM (option: NBR)
Case
Aluminium, EN AC–Al Si9Cu3(Fe), black lacquered
Window
Plastic
Weight
approx. 1.4 kg
Electrical contact
(for DELTA-comb model DPGS40 and DELTA-switch model DPS40)
Type of contact
Micro switch
Contact functions
Single (change-over)
contact 850.3
Double (change-over)
contact 850.3.3
Load data
Voltage AC
Voltage DC
U max.
250 V
30 V
I max.
5 A
0.4 A
P max.
250 VA
10 W
Switch point setting
from the outside at assistant scale by means of
adjustment screw(s)
Setting range
from 10 % to 100 % of the full scale value
Switch point reproducibility
≤ 1.6 %
Switch hysteresis
max. 5 % of the full scale value (option: max. 2.5 %)
Electrical connection
Cable gland M20 x 1.5 with 1 m free cable
For further specifications see the corresponding product label, WIKA data sheet
and the order documentation.