beautypg.com

Specifications – WIKA PSD-31 User Manual

Page 12

background image

12

WIKA operating instructions pressure switch model PSD-3x

GB

11430486.06 02/2012 GB/D/F/E

3. Specifications

Temperature coefficients in rated temperature range
Mean TC zero point: ≤ ±0.2 % of span/10 K (typical)

Mean TC span:

≤ ±0.1 % of span/10 K (typical)

3.6 Reference conditions
Temperature:

15 ... 25 °C

Atmospheric pressure: 950 ... 1,050 mbar

Humidity:

45 ... 75 % relative

Nominal position:

Process connection lower mount (LM)

Power supply:

DC 24 V

Load:

see output signals

3.7 Operating conditions
Temperatures and humidity
Medium temperature:

-20 ... +85 °C

Ambient temperature:

-20 ... +80 °C

Storage temperature:

-20 ... +80 °C

Rated temperature range: 0 ... 80 °C

Permissible humidity:

45 ... 75 % relative

Mechanics
Mounting position:

as required

Vibration resistance: 10 g (IEC 60068-2-27, under resonance)

Shock resistance:

50 g (IEC 60068-2-6, mechanical)

Service life:

10 million load cycles

Ingress protection

IP 65 and IP 67

The stated ingress protection (per IEC 60529) only applies when plugged in using mating connectors that have the appropriate ingress

protection.