Safety / 3. specifications, Specifications – WIKA O-10 User Manual
Page 9
9
WIKA operating instructions pressure transmitter model O-10
GB
11613017.04 05/2013 GB/D/F/E
2. Safety / 3. Specifications
CE, Communauté Européenne
Instruments bearing this mark comply with the relevant European directives.
Voltage DC
3. Specifications
3.1 Measuring ranges model O-10 (T)
Relative pressure
bar
0 ... 6
1) 2)
0 ... 10
1) 2)
0 ... 16
0 ... 25
0 ... 40
0 ... 60
0 ... 100
0 ... 160
0 ... 250
0 ... 400
0 ... 600
psi
0 ... 100
1) 2)
0 ... 160
0 ... 200
0 ... 250
0 ... 300
0 ... 400
0 ... 500
0 ... 600
0 ... 750
0 ... 800
0 ... 1,000
0 ... 1,500
0 ... 2,000
0 ... 3,000
0 ... 4,000
0 ... 5,000
0 ... 6,000
0 ... 7,500
0 ... 8,000
Vacuum and +/- measuring range
bar
-1 ... +5
2)
-1 ... +9
2)
-1 ... +15
-1 ... +24
-1 ... +39
-1 ... +59
psi
-30 inHg ... +100
2)
-30 inHg ... +160
-30 inHg ... +200 -30 inHg ... +300 -30 inHg ... +500
1) Measuring deviation of the zero signal ≤ ±0.7 % of span
2) Non-linearity ≤ ±0.6 % of span BFSL
The given measuring ranges are also available in kg/cm
2
, kPa and MPa.