Commissioning, operation, Output data (from master) input data explanation – WIKA D-11-7 User Manual
Page 18

18
WIKA operating instructions pressure transmitter model D-1x-7
2478159.05 12/2011 GB/D/F/E
GB
6. Commissioning, operation
Overview of services
Output data
(from master)
Input data
Explanation
Byte 1 Byte 2 Byte 3
Service request
(byte 6)
Service response 1
(byte 7)
Service response 2
(byte 8)
0x01
XX
XX
0x01
ISE-SW
AWE-SW
Software version
0x02
XX
XX
0x02
ISE-HW
AWE-HW
Hardware version
0x03
XX
XX
0x03
MBA (value)
Measuring range factor Initial pressure
0x04
XX
XX
0x04
MBE (value)
Measuring range factor End of measuring range
0x08
XX
XX
0x08
Month
Year
Date of manufacture
0x10
0x10
Res.
0x12
0x12
Res.
0x14
0x14
Res.
0x15
0x15
Res.
0x1C
0x1C
Res.
0x1D
0x1D
Res.
0x21
XX
XX
0x21
HI
LO
Read zero adjustment
0x22
XX
XX
0x22
HI
LO
Read span correction
0x23
HI
LO
0x23
HI
LO
Write zero adjustment
0x24
HI
LO
0x24
HI
LO
Write span correction
0x42
0x42
Res.
0x44
0x44
Res.
0x54
XX
XX
0x54
Sign
Temperature value
Read temperature
0x60
0x60
Res.
0x61
0x61
Res.
0x88
XX
XX
The 8 byte input data all display 0xFF
Software reset