Commissioning, operation – WIKA D-11-7 User Manual
Page 14
14
WIKA operating instructions pressure transmitter model D-1x-7
2478159.05 12/2011 GB/D/F/E
GB
Connection diagram
6. Commissioning, operation
Variant 2, customer-specific
Supply voltage
Profibus
®
connection
Circular connector, 4-pin, male, M12 x 1
Circular connector, 5-pin, male, M12 x 1
1 = U
B+
1 = n.c.
2 = n.c.
2 = RxD/TxD-P/B-line
3 = U
B
-
3 = n.c.
4 = n.c.
4 = RxD/TxD-N/A-line
5 = shield
Variant 1, per PNO recommendation
Supply voltage
Profibus
®
connection
Circular connector, 5-pin, male, M12 x 1
Female connector, 5-pin, per general Profibus® connec-
tion technology with inverted mechanical coding, M12 x 1
1 = U
B+
1 = n.c.
2 = n.c.
2 = RxD/TxD-N/A-line
3 = U
B
-
3 = n.c.
4 = n.c.
4 = RxD/TxD-P/B-line
5 = n.c.
5 = shield
This manual is related to the following products: