RC-63DLN

Overview

7

#

Feature

Function

10 K-NET TERM Switch Slide upwards (in the direction of the arrow) for K-NET

termination, slide downwards to leave bus unterminated. The last
physical device on a K-NET bus must be terminated

You can reach the KNET termination switch by inserting a small
screwdriver into the gap between the rear panel PCB and the metal
rear panel cover.

11 RESET TO

DEFAULT Button

Disconnect the power and then connect it while pressing the
RESET TO DEFAULT button (using a small screwdriver). The
unit will power up and load its memory with the factory default
KNET ID auxiliary setting (ID=2).

This operation should be carried out by authorized Kramer technical
personnel or by a qualified system integrator. You can access the
button by inserting a small screwdriver into the gap between the PCB
and the metal rear panel cover

3.2.2

The RC-63DLN Rear Panel Version for Europe

This section shows the rear panel of the RC-63DLN European version.

Section

3.2.3

defines the Reset to Default button.

Figure 3: RC-63DLN Rear Panel for Europe