beautypg.com

N 7.3, On 7.3, Ection 7.3 – Kramer Electronics VS-66H3 User Manual

Page 16

background image

Operating the VS-66H3 6x6 HDMI Matrix Switcher

13

7.3 Storing and Recalling a Switching Setting from a Preset

The STO and RCL buttons are used to store and recall up to 12 setups

which are assigned using the 6 output (preset 1 to 6) and 6 input (preset 7 to

12) buttons.
To store a preset

1

1. Configure the switching as required for the preset (for example, Input 4

to Output 3).

(for example, Input 4/Output 3 in preset 10):

2. Press the STO button.

The STO button flashes.

3. Select an OUT or IN SELECT button to store the device setting (for

example, IN 4 for preset 10).

4. Press the LOCK button

2

To recall a preset (for example, preset 10):

to store the current setup.

The STO button stops flashing.

1. Press the RCL button.

The RCL button flashes.

2. Press the relevant OUT or IN button that stored the preset (for

example, IN 4/preset 10).

3. Press the LOCK button to recall the stored preset.

The RCL button stops flashing.

7.4 Resetting the VS-66H3 6x6 HDMI Matrix Switcher’s IP

Parameters
Note:
This procedure resets only the IP related parameters. All switching

and preset values remain unchanged.
To reset the IP parameters to their default values (see

Table 4

):

Press and hold the ETH Reset button on the rear panel while

powering up the device

7.5 Connecting to the VS-66H3 6x6 HDMI Matrix Switcher via

RS-232
You can connect to the VS-66H3 via an RS-232 connection using, for

example, a PC. Note that a null-modem adapter/connection is not required.

1 You can set each of the inputs/outputs independently; you are not limited to a single input/output combination
2 You have to press the LOCK button within 10 seconds or the procedure automatically times out