VS-4228 - Connecting the VS-4228

11

4.2

Connecting a PC or Controller to the RS-485 Port

You can operate the VS-4228 via the RS-485 port from a distance of up to 1200m

(3900ft) using any device equipped with an RS-485 port (for example, a PC). For

successful communication, you must set the RS-485 machine number and bus

termination.

To connect a device with a RS-485 port to the VS-4228:

Connect the A (+) pin on the RS-485 port of the PC to the A (+) pin on the

RS-485 port on the rear panel of the VS-4228

Connect the B (–) pin on the RS-485 port of the PC to the B (–) pin on the

RS-485 port on the rear panel of the VS-4228

Connect the G pin on the RS-485 port of the PC to the G pin on the RS-485

port on the rear panel of the VS-4228

4.3

Cascading Multiple Units

You can cascade up to eight individual VS-4228 units to switch up to 64

master/slave devices using either the RS-232 (see

Section 4.3.1

) or RS-485 (see

Section 4.3.2

) interfaces.

When cascading two or more devices, you must set a unique machine number for

each device.

To set the machine number:

1. Turn the VS-4228 ON. The flashing digit in the display is the machine

number of the device.

2. To set another number, press the SLAVE button of the desired number while

the digit is flashing. The digit changes to the new number. When it stops

flashing, the new machine number is set.