2. Parameters of the SPC11 for the DGP(I)(L)-...

2-23

Festo P.BE-SPC11-DGP-EN en 0012NH

DGP(I)(L)-50-1500 to ...-50-2000 in horizontal operation

DGP(I)(L)-50-1500

DGP(I)(L)-50-1750

DGP(I)(L)-50-2000

MPYE-5-3/8-010B

MPYE-5-3/8-010B

MPYE-5-3/8-010B

Ma

ss

[k

g

]

Amplif

ic

a

tion

st

a

ge

Cushion

in

g

st

a

g

e

Sys

te

m

p

a

ra

m

e

te

r

Ti

m

e

[s

]

Amplif

ic

a

tion

st

a

ge

Cushion

in

g

st

a

g

e

Sys

te

m

p

a

ra

m

e

te

r

Ti

m

e

[s

]

Amplif

ic

a

tion

st

a

ge

Cushion

in

g

st

a

g

e

Sys

te

m

p

a

ra

m

e

te

r

Ti

m

e

[s

]

8

25

25

37

1.48

27

25

37

1.71

29

25

38

1.96

16

28

27

37

1.48

29

27

37

1.73

31

28

38

1.96

24

29

29

37

1.54

31

29

37

1.76

32

31

38

2.01

32

30

31

37

1.58

32

31

37

1.80

34

31

38

1.98

40

31

32

37

1.59

33

32

37

1.80

34

34

38

2.06

48

32

32

37

1.55

34

33

37

1.79

35

35

38

2.07

56

33

33

37

1.60

34

34

37

1.83

36

34

38

2.05

64

33

35

37

1.62

35

34

37

1.83

36

35

38

2.06

72

34

34

37

1.57

35

35

37

1.86

37

36

38

2.10

80

34

35

37

1.60

36

36

37

1.86

37

37

38

2.11

88

34

37

37

1.68

36

36

37

1.88

38

37

38

2.11

96

35

36

37

1.67

37

37

37

1.90

38

38

38

2.14

104

35

37

37

1.70

37

37

37

1.90

38

38

38

2.13

112

35

37

37

1.69

37

38

37

1.93

39

39

38

2.16

120

36

38

37

1.70

37

38

37

1.92

39

39

38

2.17