1. Summary of components

1-18

Festo P.BE-SPC11-DGP-EN en 0012NH

Using the complete cylinder stroke

If using complete the cushioning length, please observe the
following:

If the DGP(L)-... is used, the potentiometer must be longer
than the cylinder stroke used. There must be an electric
reserve. The following maximum stroke lengths can be
used:

Measuring system length
[mm]

Max. usable stroke length
[mm]

225

215

300

290

360

350

450

440

500

490

600

590

750

735

1000

985

1250

1230

1500

1475

1750

1720

2000

1965

S Mount the measuring system and the drive symmetrically,

so that the centre of the measuring system stroke
matches the centre of the complete drive stroke (see also
System manual type P.BE-SPC11-SYS-...).

The resulting positioning times depend on the actual
stroke length used.