Using the complete cylinder stroke – Festo Контроллер крайних положений SPC11 User Manual
Page 30
1. Summary of components
1-18
Festo P.BE-SPC11-DGP-EN en 0012NH
Using the complete cylinder stroke
If using complete the cushioning length, please observe the
following:
–
If the DGP(L)-... is used, the potentiometer must be longer
than the cylinder stroke used. There must be an electric
reserve. The following maximum stroke lengths can be
used:
Measuring system length
[mm]
Max. usable stroke length
[mm]
225
215
300
290
360
350
450
440
500
490
600
590
750
735
1000
985
1250
1230
1500
1475
1750
1720
2000
1965
S Mount the measuring system and the drive symmetrically,
so that the centre of the measuring system stroke
matches the centre of the complete drive stroke (see also
System manual type P.BE-SPC11-SYS-...).
–
The resulting positioning times depend on the actual
stroke length used.