Festo Контроллер крайних положений SPC11 User Manual
Page 25
1. Installation instructions for the DNCM-...-POT
1-13
Festo P.BE-SPC11-DNCM-EN en 0204NH
Mass load ( aJ )
Fit the mass load free of play.
Warning
Transverse loadings will falsify the measuring results and
possibly damage the measuring system.
•
Use an external guide for the work load in order to
prevent transverse loadings on the connecting rod of the
measuring system.
Possible moveable mass loads see “Parameters for the
DNCM-...-POT” in chapter 2. The tables listed there contain all
the combinations of drives, valves and mass loads permitted
for operation with the SPC11 type SPC11-POT-TLF.