1. Installation instructions for the DNCM-...-POT
1-7
Festo P.BE-SPC11-DNCM-EN en 0204NH
Compressed air tubing and screw connectors (4)
See also system manual type P.BE-SPC11-SYS...
•
Arrange the tubing between the valve (MPYE-5-...) and the
cylinder (DNCM-...) symmetrically.
Recommendation: Tubing length = cylinder length + 50 mm
•
Select the tubing and the connectors as shown in the fol-
lowing table.
Horizontal fitting position
Stroke length
i
Valve type MPYE-...
Screw connectors for
Tubing type PUN
in mm
MPYE-...
DNC-...
DNCM-32-...-POT
100...400
MPYE-5-1/8-LF-010B
QS-1/8-8
QS-1/8-8
PUN-8x1.25
500
MPYE-5-1/8-HF-010B
QS-1/8-8
QS-1/8-8
PUN-8x1.25
DNCM-50-...-POT
100...250
MPYE-5-1/8-LF-010B
QS-1/8-8
QS-1/4-8
PUN-8x1.25
320...400
MPYE-5-1/8-HF-010B
QS-1/8-8
QS-1/4-8
PUN-8x1.25
500
MPYE-5-1/4-010B
QS-1/4-10
QS-1/4-10
PUN-10x1.5